Tunable Interband Cascade Laser-Based Mid-Infrared Spectroscopy for Protein Sensing: Wavenumber-Resolved Performance Evaluation within the Amide I Region
Journal of Analysis and Testing · 31.07.2026
DOI: 10.1007/s41664-026-00473-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Analysis and Testing, online erschienen am 31.07.2026. Verfasst von Mehmet Can Erdem und 10 weiteren Autor:innen. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Norwegian University of Life Sciences.
Abstract (Originalsprache)
Compact mid-infrared (MIR) spectrometers based on tunable interband cascade lasers (tICLs), which are integrated with thin-film waveguides, represent a promising platform for discrete-emission spectroscopic measurements in aqueous systems, operating across the amide I region (1692–1640 cm − 1 ). This study presents a wavenumber-resolved performance evaluation of a prototype tICL-based spectrometer using bovine serum albumin (BSA) standards at different concentrations to assess the limit of detection (LOD), limit of quantification (LOQ), and signal-to-noise ratio (SNR), while benchmarking its performance against a compact Fourier-transform infrared attenuated total reflectance (FTIR-ATR) system to contextualize analytical behavior. Although the prototype showed acceptable initial performance, system-induced variability affected the analytical sensitivity and reproducibility of the measurements. To address these limitations, a wavenumber-resolved analytical framework was applied to quantify sample-induced spectral variations. Absorbance variation was analyzed at individual emission points, focusing on concentration dependence and replicate consistency. Using the strictly standardized mean difference (SSMD) metric and z -score standardization, wavenumbers were ranked by concentration-level discriminability, with those having positive z -scores selected for further analysis. When applied to an independent dataset, the SSMD-based selection yielded lower LOD (1.24% to 0.71%) and LOQ (3.75% to 2.17%), reflecting improved analytical sensitivity through channel selection. Partial least-squares regression (PLSR) score-space clustering further demonstrated enhanced separation of BSA concentrations with SSMD-filtered subsets. Overall, the proposed wavenumber-resolved performance framework enabled the selection of high-quality emission points, supporting the optimization of compact tICL-based MIR spectrometers for protein-relevant analytical measurements and industrial process-monitoring contexts.
Förderung
- Norwegian University of Life Sciences
Zitieren
APA
Erdem, M. C., Kafle, B., Karki, P., Blazhko, U., Zimmermann, B., Brandsrud, M. A., Scheuermann, J., Weih, R., Koeth, J., Mizaikoff, B., & Kohler, A. (2026). Tunable Interband Cascade Laser-Based Mid-Infrared Spectroscopy for Protein Sensing: Wavenumber-Resolved Performance Evaluation within the Amide I Region. Journal of Analysis and Testing. https://doi.org/10.1007/s41664-026-00473-3
Vancouver
Erdem MC, Kafle B, Karki P, Blazhko U, Zimmermann B, Brandsrud MA, et al. Tunable Interband Cascade Laser-Based Mid-Infrared Spectroscopy for Protein Sensing: Wavenumber-Resolved Performance Evaluation within the Amide I Region. Journal of Analysis and Testing. 2026. doi:10.1007/s41664-026-00473-3
BibTeX
@article{Erdem2026,
author = {Erdem, Mehmet Can and Kafle, Bijay and Karki, Pranish and Blazhko, Uladzislau and Zimmermann, Boris and Brandsrud, Maren Anna and Scheuermann, Julian and Weih, Robert and Koeth, Johannes and Mizaikoff, Boris and Kohler, Achim},
title = {Tunable Interband Cascade Laser-Based Mid-Infrared Spectroscopy for Protein Sensing: Wavenumber-Resolved Performance Evaluation within the Amide I Region},
journal = {Journal of Analysis and Testing},
year = {2026},
doi = {10.1007/s41664-026-00473-3}
}
EUVIMED