Effects of Attachment Design and Aligner Material on Mandibular Canine Distal Bodily Movement in Aligner Treatment
Journal of Medical and Biological Engineering · 2024-10 · 44 (5) · 777-787
DOI: 10.1007/s40846-024-00904-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical and Biological Engineering, online erschienen am 05.10.2024. Verfasst von Pin-Yu Chen und 3 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Medical University, Taiwan.
Abstract (Originalsprache)
Purpose
Dental crowding is a result of a mismatch between tooth size and arch dimensions, which leads to malocclusion; treatment often involves premolar extraction before orthodontic alignment. Clear aligners are limited in their ability to achieve canine distal bodily movement, a common orthodontic maneuver. This study investigated the impacts of attachment design and aligner material on the efficacy of canine distal bodily movement.
Methods
A finite element analysis was conducted to examine the impact of various attachment designs and two aligner materials, thermoplastic polyurethanes/polycarbonate (TPU/PC) and polyethylene terephthalate glycol-modified (PETG), on mandibular canine distal bodily movement. The investigation focused on the biomechanical responses in the periodontal ligament (PDL) and surrounding alveolar bone.
Results
Attachment configuration exerted a strong influence on mandibular canine movement. Vertically oriented attachment pairs positioned mesially (mesial occlusal–mesial cervical) resulted in the most effective canine distal bodily movement, followed by a rectangular attachment. TPU/PC aligners induced slightly higher principal stresses in the PDL and von Mises stress and strain in the surrounding alveolar bone compared with PETG aligners; however, the difference was negligible, amounting to less than 6%.
Conclusion
Attachment design, specifically vertically oriented pairs positioned mesially (mesial occlusal–mesial cervical), was determined to be the crucial factor influencing the efficacy of canine distal bodily movement. The choice of aligner material (TPU/PC or PETG) has minimal impact on this orthodontic procedure.
Förderung
- China Medical University, Taiwan
Zitieren
APA
Chen, P., Huang, H., Yu, J., & Hsu, J. (2024). Effects of Attachment Design and Aligner Material on Mandibular Canine Distal Bodily Movement in Aligner Treatment. Journal of Medical and Biological Engineering, 44(5), 777-787. https://doi.org/10.1007/s40846-024-00904-5
Vancouver
Chen P, Huang H, Yu J, Hsu J. Effects of Attachment Design and Aligner Material on Mandibular Canine Distal Bodily Movement in Aligner Treatment. Journal of Medical and Biological Engineering. 2024;44(5):777-787. doi:10.1007/s40846-024-00904-5
BibTeX
@article{Chen2024,
author = {Chen, Pin-Yu and Huang, Heng-Li and Yu, Jian-Hong and Hsu, Jui-Ting},
title = {Effects of Attachment Design and Aligner Material on Mandibular Canine Distal Bodily Movement in Aligner Treatment},
journal = {Journal of Medical and Biological Engineering},
year = {2024},
volume = {44},
number = {5},
pages = {777--787},
doi = {10.1007/s40846-024-00904-5}
}