Ultrasound-derived muscle thickness and muscle quality parameters vary across regions of the vastus lateralis in physically active and endurance-trained men
Journal of Ultrasound · 04.11.2026
DOI: 10.1007/s40477-026-01248-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound, online erschienen am 04.11.2026. Verfasst von Giuseppe Rosaci und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department for Life Quality Studies, University of Bologna, Bologna, Italy. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Purpose
This study primarily investigated differences in muscle thickness (MT), corrected echo intensity (cEI), subcutaneous fat thickness (SFT) and predicted fat fraction (FF%) across regions/sites of the vastus lateralis (VL) muscle. A secondary exploratory aim was to compare these parameters between endurance-trained and physically active men groups.
Methods
Measurements were obtained from four groups of men (physically active individuals, cyclists, runners, and triathletes; n = 26; 29.2 ± 8.4 y, 75.3 ± 12.3 kg, 176.8 ± 8.3 cm). Panoramic B-mode ultrasound was used to assess cEI and FF% at 0–25%, 25–50%, 50–75% and 75–100% of the muscle length. MT and SFT were assessed at the midpoints of each region (12.5%, 37.5%, 62.5%, and 87.5%). One-way repeated-measures ANOVA compared regions and sites with pooled groups, while one-way ANOVA compared groups. Results cEI was significantly lower in the middle (25–75%) than in both the distal (0–25%) and proximal (75–100%) regions ( p ≤ 0.002, g = 0.61–0.79). FF% was higher in the proximal region than in all other regions ( p ≤ 0.025, g = 0.61–0.92), and higher at 25–50% than 0–25% ( p = 0.011, g = 0.31). SFT was greater at 87.5% than at all other sites ( p 0.05).
Conclusion
All parameters may vary along the VL muscle belly. Ultrasound-derived assessments of muscle architecture and quality based on a single measurement site/region should be interpreted with caution.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department for Life Quality Studies, University of Bologna, Bologna, Italy.
- Biomechanics Laboratory, Federal University of Santa Catarina, Florianópolis, Brazil.
- Department for Life Quality Studies, University of Bologna, Bologna, Italy. Sandro.bartolomei@unibo.it.
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Rosaci, G., Lunardi, M., Bartolomei, S., Sakugawa, R. L., & Diefenthaeler, F. (2026). Ultrasound-derived muscle thickness and muscle quality parameters vary across regions of the vastus lateralis in physically active and endurance-trained men. Journal of Ultrasound. https://doi.org/10.1007/s40477-026-01248-3
Vancouver
Rosaci G, Lunardi M, Bartolomei S, Sakugawa RL, Diefenthaeler F. Ultrasound-derived muscle thickness and muscle quality parameters vary across regions of the vastus lateralis in physically active and endurance-trained men. Journal of Ultrasound. 2026. doi:10.1007/s40477-026-01248-3
BibTeX
@article{Rosaci2026,
author = {Rosaci, Giuseppe and Lunardi, Morgana and Bartolomei, Sandro and Sakugawa, Raphael Luiz and Diefenthaeler, Fernando},
title = {Ultrasound-derived muscle thickness and muscle quality parameters vary across regions of the vastus lateralis in physically active and endurance-trained men},
journal = {Journal of Ultrasound},
year = {2026},
doi = {10.1007/s40477-026-01248-3}
}
EUVIMED