CEUS for the diagnosis of acute graft pyelonephritis in renal transplant recipients
Journal of Ultrasound · 26.09.2026 · 29 (4) · 893-900
DOI: 10.1007/s40477-026-01228-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Ultrasound, online erschienen am 26.09.2026. Verfasst von Andrea Boccatonda und 10 weiteren Autor:innen. Beteiligte Einrichtung: Diagnostic and Therapeutic Interventional Ultrasound Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico Sant'Orsola-Malpighi, via …. Hauptthemen laut MEDLINE: Kidney Transplantation, Pyelonephritis, Contrast Media, Postoperative Complications. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Acute graft pyelonephritis (AGPN) is a clinically relevant complication in renal transplant recipients, in whom diagnosis may be challenging because of nonspecific clinical and conventional ultrasound findings. Contrast-enhanced ultrasound (CEUS) enables real-time assessment of renal microvascular perfusion without nephrotoxic contrast agents. This study aimed to evaluate the diagnostic performance of CEUS for detecting AGPN in renal transplant recipients.
Methods
This retrospective single-center study included 66 consecutive renal transplant recipients who underwent CEUS for clinically suspected AGPN. The final clinical diagnosis, based on the integration of clinical, laboratory, microbiological, and available imaging findings, was used as the reference standard. Conventional ultrasound findings and CEUS parenchymal perfusion abnormalities were assessed. Diagnostic performance was evaluated in terms of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratios.
Results
AGPN was confirmed in 21/66 patients (31.8%). Fever was more frequent in patients with AGPN than in those without AGPN (100% vs. 73.3%, p=0.014). On conventional ultrasound, globular graft appearance (14.3% vs. 0%, p=0.029), cortical hyperechogenicity (23.8% vs. 0%, p=0.002), cortical hypoechogenicity (28.6% vs. 4.4%, p=0.010), perirenal fluid collection (38.1% vs. 11.1%, p=0.018), and ureteral wall thickening (42.9% vs. 8.9%, p=0.002) were significantly associated with AGPN. CEUS correctly identified 19/21 AGPN cases, with two false-negative and no false-positive examinations. Sensitivity was 90.5% (95% CI 69.6–98.8%), specificity 100% (95% CI 92.1–100%), PPV 100% (95% CI 82.4–100%), and NPV 95.7% (95% CI 85.5–99.5%).
Conclusion
CEUS showed high diagnostic accuracy for AGPN in renal transplant recipients. By providing real-time assessment of graft parenchymal perfusion without nephrotoxicity or ionizing radiation, CEUS may represent a valuable complement to conventional ultrasound and potentially reduce the need for contrast-enhanced CT in selected patients. Larger prospective multicenter studies with standardized independent reference standards are warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Diagnostic and Therapeutic Interventional Ultrasound Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico Sant'Orsola-Malpighi, via Massarenti n 9, 40138, Bologna, Italy. andrea.boccatonda2@unibo.it.
- Diagnostic and Therapeutic Interventional Ultrasound Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico Sant'Orsola-Malpighi, via Massarenti n 9, 40138, Bologna, Italy.
- Division of Urology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
- Nephrology, Dialysis and Kidney Transplant Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
Zitieren
APA
Boccatonda, A., Brighenti, A., Tiraferri, V., Musmeci, M., Agostinelli, D., Venturoli, N., Masi, L., Barretta, A., Gessaroli, E., Comai, G., & Serra, C. (2026). CEUS for the diagnosis of acute graft pyelonephritis in renal transplant recipients. Journal of Ultrasound, 29(4), 893-900. https://doi.org/10.1007/s40477-026-01228-7
Vancouver
Boccatonda A, Brighenti A, Tiraferri V, Musmeci M, Agostinelli D, Venturoli N, et al. CEUS for the diagnosis of acute graft pyelonephritis in renal transplant recipients. Journal of Ultrasound. 2026;29(4):893-900. doi:10.1007/s40477-026-01228-7
BibTeX
@article{Boccatonda2026,
author = {Boccatonda, Andrea and Brighenti, Alice and Tiraferri, Valeria and Musmeci, Marco and Agostinelli, Daniela and Venturoli, Nicola and Masi, Livia and Barretta, Attilio and Gessaroli, Elisa and Comai, Giorgia and Serra, Carla},
title = {CEUS for the diagnosis of acute graft pyelonephritis in renal transplant recipients},
journal = {Journal of Ultrasound},
year = {2026},
volume = {29},
number = {4},
pages = {893--900},
doi = {10.1007/s40477-026-01228-7}
}
EUVIMED