Dynamic compressive behavior of steel microfiber-reinforced grout: experimental investigation and statistical optimization
Journal of the Brazilian Society of Mechanical Sciences and Engineering · 2026-04 · 48 (4)
DOI: 10.1007/s40430-025-06236-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Brazilian Society of Mechanical Sciences and Engineering, online erschienen am 18.03.2026. Verfasst von Mahmoud M. Awd Allah und 4 weiteren Autor:innen. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Southern Methodist University.
Abstract (Originalsprache)
This work investigates the mechanical behavior of grout reinforced with steel wool microfibers under dynamic compressive loading. Four fiber volume fractions (FVFs), i.e., 0.0, 0.5, 1.0, and 1.5%, were incorporated into the grout mixture to assess their influences on compressive strength, ultimate strain, and energy absorption capacity. Dynamic testing was conducted using a split Hopkinson pressure (Kolsky) bar equipped with precisely designed pulse shapers to achieve constant strain rate deformation and dynamic stress equilibrium. Meanwhile, quasi-static tests were performed to evaluate the influence of FVFs on the dynamic increase factor (DIF). To investigate failure probabilities and repeatability, the experimental results were analyzed using the two-parameter Weibull distribution function. Furthermore, an integrated multi-attribute decision-making (MADM) approach, combining the Analytic Hierarchy Process (AHP) and the Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS), was employed to determine the optimal FVF for enhancing the grout performance. By systematically investigating the relationships between fiber content, dynamic compressive response, statistical reliability, and multi-criteria optimization, this study establishes an evidence-based framework to determine the optimal steel FVF. The results highlighted the importance of optimizing steel FVF to enhance the dynamic performance of grout. According to the AHP-TOPSIS analysis, the grout-FVF0.5 specimen, which incorporates 0.5% FVF, revealed the most optimum compressive performance under high strain-rate loading conditions.
Förderung
- Southern Methodist University
Zitieren
APA
Allah, M. M. A., Abbas, M. A., Williams, B. A., Heard, W. F., & Nie, X. (2026). Dynamic compressive behavior of steel microfiber-reinforced grout: experimental investigation and statistical optimization. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 48(4). https://doi.org/10.1007/s40430-025-06236-y
Vancouver
Allah MMA, Abbas MA, Williams BA, Heard WF, Nie X. Dynamic compressive behavior of steel microfiber-reinforced grout: experimental investigation and statistical optimization. Journal of the Brazilian Society of Mechanical Sciences and Engineering. 2026;48(4). doi:10.1007/s40430-025-06236-y
BibTeX
@article{Allah2026,
author = {Allah, Mahmoud M. Awd and Abbas, Mohamed A. and Williams, Brett A. and Heard, William F. and Nie, Xu},
title = {Dynamic compressive behavior of steel microfiber-reinforced grout: experimental investigation and statistical optimization},
journal = {Journal of the Brazilian Society of Mechanical Sciences and Engineering},
year = {2026},
volume = {48},
number = {4},
doi = {10.1007/s40430-025-06236-y}
}