Real-Time Detection of Colorectal Cancer Using Topical Application of a pH-Activatable Fluorophore

Daan G J Linders, Jinhui Ser, Md Shamim, Aida Baibussunova, Jasmijn C J Loggers, Gilbert Noordam, Davey van den Burg, Gijs J D van Acker, Onno R Guicherit, Marinke Westerterp, Peter J K Kuppen, Andreas W K S Marinelli und 6 weitere

Molecular Diagnosis & Therapy · 2026

DOI: 10.1007/s40291-026-00853-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecular Diagnosis & Therapy, 2026. Verfasst von Daan G J Linders und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands. Hauptthemen laut MEDLINE: Colorectal Neoplasms, Fluorescent Dyes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NCI NIH HHS, Ministry of Health & Welfare (S. Korea), Ministry of Health & Welfare and Ministry of Science and ICT (S. Korea).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Standard treatment for locally advanced rectal cancer involves neoadjuvant chemoradiation therapy (nCRT) followed by total mesorectal excision, but this approach carries significant morbidity and often results in incomplete resections owing to poor intraoperative tumor visualization. For patients with complete response to nCRT, a watch-and-wait (W&W) strategy can spare surgery, but current imaging techniques inadequately identify complete responders, leading to regrowth in ~ 30% of cases. To improve nCRT response assessment and guide resections, we developed PH10, a topically applied, pH-activatable near-infrared (NIR) fluorescent probe for rapid, tumor-specific imaging. METHODS: PH10, a small-molecule cyanine analog, was tested in murine models and on human tumor specimens (n = 11). Fluorescence activation, tumor specificity, and tumor-to-background ratio (TBR) were evaluated in vivo and ex vivo within clinically relevant timeframes. RESULTS: PH10 enabled rapid and specific tumor visualization, achieving a median TBR of 3.2 within 1 min in vivo in murine models and 2.2 within 10 min ex vivo on human samples. The probe demonstrated high specificity for tumor tissue within the acidic tumor microenvironment without requiring systemic administration or prolonged incubation. CONCLUSIONS: PH10 is a promising, fast-acting topical NIR agent for real-time tumor detection during colorectal cancer endoscopy and surgery. Its simplicity and rapid kinetics support potential clinical translation. Moreover, its pH-activatable mechanism may extend its utility to other solid cancers with acidic microenvironments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Colorectal NeoplasmsFluorescent DyesHumansAnimalsHydrogen-Ion ConcentrationMiceCell Line, TumorFemaleFluorescent Chemosensor CompoundsAdministration, TopicalDisease Models, AnimalOptical Imaging

Substanzen

Fluorescent DyesFluorescent Chemosensor Compounds

Autor:innen und Institutionen

  • Department of Surgery, Leiden University Medical Center, 2333 ZA, Leiden, The Netherlands.
  • Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, 02114, USA.
  • Department of Chemistry, Center of Diagnostics and Therapeutics, Georgia State University, Atlanta, GA, 30303, USA.
  • Department of Pathology, Haaglanden Medical Center, 2512 VA, The Hague, The Netherlands.
  • Department of Surgery, Haaglanden Medical Center, 2512 VA, The Hague, The Netherlands.
  • Department of Surgical Oncology and Gastrointestinal Surgery, Erasmus MC Cancer Institute, University Medical Center Rotterdam, 3015 GD, Rotterdam, The Netherlands.

Förderung

  • NCI NIH HHS
  • Ministry of Health & Welfare (S. Korea)
  • Ministry of Health & Welfare and Ministry of Science and ICT (S. Korea)
  • Foundation for the National Institutes of Health
  • the Leiden University Fund
  • Prof. Michaël-van Vloten Fund
  • Stichting de Drie Lichten
  • Nederlandse Vereniging voor Gastroenterologie

Zitieren

APA

Linders, D. G. J., Ser, J., Shamim, M., Baibussunova, A., Loggers, J. C. J., Noordam, G., van den Burg, D., van Acker, G. J. D., Guicherit, O. R., Westerterp, M., Kuppen, P. J. K., Marinelli, A. W. K. S., Hilling, D. E., Peters, E. E. M., Kashiwagi, S., Henary, M., Choi, H. S., & Vahrmeijer, A. L. (2026). Real-Time Detection of Colorectal Cancer Using Topical Application of a pH-Activatable Fluorophore. Molecular Diagnosis & Therapy. https://doi.org/10.1007/s40291-026-00853-6

Vancouver

Linders DGJ, Ser J, Shamim M, Baibussunova A, Loggers JCJ, Noordam G, et al. Real-Time Detection of Colorectal Cancer Using Topical Application of a pH-Activatable Fluorophore. Molecular Diagnosis & Therapy. 2026. doi:10.1007/s40291-026-00853-6

BibTeX
@article{Linders2026,
  author = {Linders, Daan G J and Ser, Jinhui and Shamim, Md and Baibussunova, Aida and Loggers, Jasmijn C J and Noordam, Gilbert and van den Burg, Davey and van Acker, Gijs J D and Guicherit, Onno R and Westerterp, Marinke and Kuppen, Peter J K and Marinelli, Andreas W K S and Hilling, Denise E and Peters, Elke E M and Kashiwagi, Satoshi and Henary, Maged and Choi, Hak Soo and Vahrmeijer, Alexander L},
  title = {Real-Time Detection of Colorectal Cancer Using Topical Application of a pH-Activatable Fluorophore},
  journal = {Molecular Diagnosis & Therapy},
  year = {2026},
  doi = {10.1007/s40291-026-00853-6}
}
Kostenlos starten →