Mitigating indoor risk of airborne infections using CO2 and PM measurements in university classroom: the MIRAI project
Journal of Environmental Health Science and Engineering · 30.05.2026 · 24 (1)
DOI: 10.1007/s40201-026-00984-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Environmental Health Science and Engineering, online erschienen am 30.05.2026. Verfasst von Riccardo Mazzoli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Environmental, Genetic and Nutritional Epidemiology Research Center (CREAGEN), Department of Biomedical, Metabolic and Neural Sciences, Section of Pu…. Die Arbeit nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Modena e Reggio Emilia.
Abstract (Originalsprache)
Background
Indoor air quality (IAQ) impacts well-being and the spread of airborne diseases, particularly in multi-occupancy environments like classrooms. Carbon dioxide (CO 2 ) and particulate matter (PM) levels have been used in continuous monitoring as indicators of indoor air quality.
Methods
We used cost-effective sensors to assess levels of CO2 and PM in two Italian university classrooms (Unit 1 and Unit 2), differing in size and ventilation, from March 2022 to May 2023. For CO2 and PM monitoring we used respectively ARANET4 sensors and Optical Particle Counters (OPC) assessing aerosol diameter size distribution between 350 nm and 40 μm in order to evaluate trends in IAQ and the influence of environmental factors including ventilation, occupancy, and season.
Results
The naturally ventilated classroom (Unit 1) exhibited higher CO2 and PM concentrations with greater variability, whereas the HVAC-supported one (Unit 2) maintained more consistent air quality but faced occasional spikes. Occupancy also affected CO2 and PM levels, with higher variability in Unit 1 characterized by lower size and generally full occupancy. Seasonal trends highlighted increased PM levels during colder months due to reduced ventilation in both units.
Conclusions
In this feasibility study, variations in building design, ventilation strategies, and occupancy dynamics were associated with corresponding patterns in IAQ, supporting the use of low-cost, user-friendly sensors as practical tools to characterize ventilation performance and to inform interventions aimed at safer learning spaces. Implementation of CO2 and PM measurements as proxy indicators of ventilation adequacy and of potential airborne infection risk, along with outreach programs and guidelines to educate teachers and students about relevance of IAQ assessment is recommended to promote occupant health and mitigate risk of airborne disease transmission.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Environmental, Genetic and Nutritional Epidemiology Research Center (CREAGEN), Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, Modena, Italy.
- School of Public Health, University of California Berkeley, Berkeley, CA USA.
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 287 Via Campi, 41125 Modena, Italy.
- DIEF - Department of Engineering 'Enzo Ferrari', University of Modena and Reggio Emilia, Modena, Italy.
- Department of Epidemiology, Boston University School of Public Health, Boston, MA USA.
ORCID-Profile: Riccardo Mazzoli, Tommaso Filippini, Grazia Ghermandi, Marco Vinceti, Alessandro Bigi
Förderung
- Università degli Studi di Modena e Reggio Emilia
Zitieren
APA
Mazzoli, R., Filippini, T., Ghermandi, G., Vinceti, M., & Bigi, A. (2026). Mitigating indoor risk of airborne infections using CO2 and PM measurements in university classroom: the MIRAI project. Journal of Environmental Health Science and Engineering, 24(1). https://doi.org/10.1007/s40201-026-00984-2
Vancouver
Mazzoli R, Filippini T, Ghermandi G, Vinceti M, Bigi A. Mitigating indoor risk of airborne infections using CO2 and PM measurements in university classroom: the MIRAI project. Journal of Environmental Health Science and Engineering. 2026;24(1). doi:10.1007/s40201-026-00984-2
BibTeX
@article{Mazzoli2026,
author = {Mazzoli, Riccardo and Filippini, Tommaso and Ghermandi, Grazia and Vinceti, Marco and Bigi, Alessandro},
title = {Mitigating indoor risk of airborne infections using CO2 and PM measurements in university classroom: the MIRAI project},
journal = {Journal of Environmental Health Science and Engineering},
year = {2026},
volume = {24},
number = {1},
doi = {10.1007/s40201-026-00984-2}
}
EUVIMED