EUVIMEDEUVIMED entdecken
Crossref

Comparison of Non-invasive Methods for Measuring Intracranial Hypertension

Danielle Santoyo, Eric Mylfurry, Marilyn Li, Mercylia Untono, Matthew Mellor, Urva Mehveen, Hariharan Ramakrishnan, David Williams, James Paxton

Current Emergency and Hospital Medicine Reports · 27.07.2026 · 14 (1)

DOI: 10.1007/s40138-026-00353-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Current Emergency and Hospital Medicine Reports, online erschienen am 27.07.2026. Verfasst von Danielle Santoyo und 8 weiteren Autor:innen. Die Arbeit nennt 58 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose of Review Intracranial hypertension (IHTN) is a serious condition associated with neurological injuries, making detection crucial to guide swift treatment. This review investigates optimal non-invasive methods for detecting IHTN in the Emergency Department by comparing the effectiveness and utility of different technologies. Recent Findings Automated infrared pupillometry (AIP) was the most cost-effective (NPi-300 cost $0.60USD/use) and timely (3 s) method within this study. CT had the highest average sensitivity (93%), and tympanic membrane displacement (TMD) had the highest average specificity (95.9%) when screening for IHTN. Alternatively, ultrasound-detected optic nerve sheath diameter (US-ONSD) provides a cost-effective ($0.75–3.75USD/use) and timely option (~ 10-min), with the second-highest sensitivity (91.9%). Summary AIP and US-ONSD are promising first-line methods to rapidly exclude IHTN in the ED. This guides decision-making on whether neuroimaging is warranted. Future studies could compare non-invasive IHTN screening combinations to create an optimized screening algorithm.

Zitieren

APA

Santoyo, D., Mylfurry, E., Li, M., Untono, M., Mellor, M., Mehveen, U., Ramakrishnan, H., Williams, D., & Paxton, J. (2026). Comparison of Non-invasive Methods for Measuring Intracranial Hypertension. Current Emergency and Hospital Medicine Reports, 14(1). https://doi.org/10.1007/s40138-026-00353-1

Vancouver

Santoyo D, Mylfurry E, Li M, Untono M, Mellor M, Mehveen U, et al. Comparison of Non-invasive Methods for Measuring Intracranial Hypertension. Current Emergency and Hospital Medicine Reports. 2026;14(1). doi:10.1007/s40138-026-00353-1

BibTeX
@article{Santoyo2026,
  author = {Santoyo, Danielle and Mylfurry, Eric and Li, Marilyn and Untono, Mercylia and Mellor, Matthew and Mehveen, Urva and Ramakrishnan, Hariharan and Williams, David and Paxton, James},
  title = {Comparison of Non-invasive Methods for Measuring Intracranial Hypertension},