Smartphone-Based Portable Slit Lamp in Anterior Segment Diseases: A Narrative Review of Clinical Assessment and Integration with Artificial Intelligence
Ophthalmology and Therapy · 2026-03 · 15 (3) · 945-965
DOI: 10.1007/s40123-026-01312-5 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Ophthalmology and Therapy, online erschienen am 10.02.2026. Verfasst von Xinyu Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: CAMS Innovation Fund for Medical Sciences, Peking Union Medical College Hospital Deposit Integration Commission Funds.
Abstract (Originalsprache)
Smartphone-based portable slit lamps are rapidly evolving from simple add-ons into practical, low-cost front-line tools for anterior segment care beyond traditional clinical settings. By integrating high-performance smartphone cameras with compact optical attachments (e.g., slit-light converters, macro lenses, blue filters) and dedicated applications, these devices deliver slit-lamp-style imaging and video capture to environments where conventional biomicroscopes are inaccessible. Accumulating clinical evidence-most notably for the Smart Eye Camera (SEC) and iSpector MINI HE 010-21-confirms that smartphone slit lamps reliably support assessments across major anterior segment disorders. SEC-based recordings enable evaluation of tear film-related signs in dry eye disease; smartphone-acquired slit-lamp images show strong agreement with standard slit lamps for corneal ulcers, scars, and other ocular surface pathologies; slit-beam acquisition facilitates preliminary screening of shallow anterior chambers and narrow angles relevant to primary angle-closure glaucoma; and cataract screening and grading via smartphone systems align closely with conventional slit-lamp evaluations. Notably, recent advancements have transcended mere image capture to embrace artificial intelligence (AI)-enabled analysis, positioning smartphone slit lamps as scalable screening and triage solutions. Across the studies reviewed, AI models trained on smartphone slit-lamp images or videos demonstrate robust feasibility for automated dry eye diagnosis, corneal opacity detection, keratitis screening, cataract grading, pterygium detection/grading, and narrow-angle identification, typically through pipelines integrating image quality control, region-of-interest localization/segmentation, and disease-specific prediction. Despite these advances, however, key barriers remain, including incomplete replication of full slit-lamp functionality, lack of standardized acquisition protocols, and limited multicenter external validation for most AI systems. Future progress should prioritize hardware stabilization, optical design improvements, disease-specific standardized imaging workflows, and large-scale prospective validation to unlock the full potential of AI-assisted smartphone slit lamps for community screening, teleophthalmology, and care in underserved regions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China.
- Key Laboratory of Ocular Fundus Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
- Beijing Key Laboratory of Fundus Diseases Intelligent Diagnosis & Drug/Device Development and Translation, Beijing, China.
- Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China. Chenyx@pumch.cn.
- Key Laboratory of Ocular Fundus Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China. Chenyx@pumch.cn.
Förderung
- CAMS Innovation Fund for Medical Sciences
- Peking Union Medical College Hospital Deposit Integration Commission Funds
Zitieren
APA
Liu, X., Meng, L., Chen, Y., & Chen, H. (2026). Smartphone-Based Portable Slit Lamp in Anterior Segment Diseases: A Narrative Review of Clinical Assessment and Integration with Artificial Intelligence. Ophthalmology and Therapy, 15(3), 945-965. https://doi.org/10.1007/s40123-026-01312-5
Vancouver
Liu X, Meng L, Chen Y, Chen H. Smartphone-Based Portable Slit Lamp in Anterior Segment Diseases: A Narrative Review of Clinical Assessment and Integration with Artificial Intelligence. Ophthalmology and Therapy. 2026;15(3):945-965. doi:10.1007/s40123-026-01312-5
BibTeX
@article{Liu2026,
author = {Liu, Xinyu and Meng, Lihui and Chen, Youxin and Chen, Huan},
title = {Smartphone-Based Portable Slit Lamp in Anterior Segment Diseases: A Narrative Review of Clinical Assessment and Integration with Artificial Intelligence},
journal = {Ophthalmology and Therapy},
year = {2026},
volume = {15},
number = {3},
pages = {945--965},
doi = {10.1007/s40123-026-01312-5}
}