Capsular Bag Performance of a Novel Hydrophobic Single-Piece Intraocular Lens
Ophthalmology and Therapy · 2025-02 · 14 (2) · 295-308
DOI: 10.1007/s40123-024-01075-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmology and Therapy, online erschienen am 12.12.2024. Verfasst von Klemens Waser und 6 weiteren Autor:innen. Beteiligte Einrichtung: Kepler University Clinic, Krankenhausstraße 9, 4020, Linz, Austria. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alcon Research Institute.
Abstract (Originalsprache)
Introduction
We conducted an evaluation of capsular bag performance of the Clareon CNA0T0 intraocular lens (IOL), focusing on postoperative anterior chamber depth (ACD), IOL tilt, and IOL decentration.
Methods
Inclusion criteria were bilateral age-related cataract and the ability to provide informed consent. Exclusion criteria were prior surgeries, combined surgeries, and conditions posing a risk for postoperative capsular bag instability. Preoperative and 8-week postoperative assessments included optical biometry and high-resolution anterior segment optical coherence tomography (OCT). Subjective refraction was conducted only at 8 weeks postoperative visit.
Results
In the first analysis, 49 right eyes of 49 patients were included. Mean preoperative and postoperative ACD were 3.10 and 4.69 mm, respectively. Mean preoperative tilt was 4.77°, increasing to 5.06° postoperatively. Preoperative decentration was 0.16 mm, increasing to 0.26 mm postoperatively. Absolute refractive error (ARE) was + 0.31D, with 81% of eyes within ± 0.5D limits. In analysis II (98 eyes of 49 patients), both eyes showed a moderate correlation in IOL tilt (Pearson correlation coefficient: 0.27, p = 0.061) and a low correlation in IOL decentration (Pearson correlation coefficient: 0.02, p = 0.892) and ARE (Spearman: 0.15, p = 305) between right and left eyes of the same patient.
Conclusions
The Clareon CNA0T0 IOL demonstrated high mechanical stability, with low postoperative tilt and decentration values, resulting in excellent refractive outcomes and visual acuity. These findings confirm the IOL’s high stability within the capsular bag and effectiveness in minimizing postoperative refractive error, requiring only minor A-constant adjustments for optimal cataract surgery outcomes. Trial Registration NCT06595693.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kepler University Clinic, Krankenhausstraße 9, 4020, Linz, Austria.
- Johannes Kepler University, Linz, Austria.
- Smile Eyes, Trier, Germany.
- Kepler University Clinic, Krankenhausstraße 9, 4020, Linz, Austria. nino.hirnschall@gmail.com.
- Johannes Kepler University, Linz, Austria. nino.hirnschall@gmail.com.
Förderung
- Alcon Research Institute
Zitieren
APA
Waser, K., Straßmair, K., Pomberger, L., Khalil, H., Laubichler, P., Bolz, M., & Hirnschall, N. (2025). Capsular Bag Performance of a Novel Hydrophobic Single-Piece Intraocular Lens. Ophthalmology and Therapy, 14(2), 295-308. https://doi.org/10.1007/s40123-024-01075-x
Vancouver
Waser K, Straßmair K, Pomberger L, Khalil H, Laubichler P, Bolz M, et al. Capsular Bag Performance of a Novel Hydrophobic Single-Piece Intraocular Lens. Ophthalmology and Therapy. 2025;14(2):295-308. doi:10.1007/s40123-024-01075-x
BibTeX
@article{Waser2025,
author = {Waser, Klemens and Straßmair, Klaus and Pomberger, Leon and Khalil, Haidar and Laubichler, Peter and Bolz, Matthias and Hirnschall, Nino},
title = {Capsular Bag Performance of a Novel Hydrophobic Single-Piece Intraocular Lens},
journal = {Ophthalmology and Therapy},
year = {2025},
volume = {14},
number = {2},
pages = {295--308},
doi = {10.1007/s40123-024-01075-x}
}
EUVIMED