Performance of ultra-sensitive electrochemiluminescence LAM assay for diagnosing tuberculosis in HIV-negative individuals: a multicentre, prospective diagnostic study
Infection · 2026-10 · 54 (5) · 2437-2445
DOI: 10.1007/s15010-026-02861-4 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Infection, online erschienen am 22.06.2026. Verfasst von Yuanyuan Shang und 13 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Key Laboratory for Key Technologies in Tuberculosis Prevention and Control, Department of Bacteriology and Immunology, Beijing Chest Hospital…. Hauptthemen laut MEDLINE: Electrochemical Techniques, Lipopolysaccharides, Luminescent Measurements, Tuberculosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Beijing Research Ward Excellence Program, Beijing Municipal Health and Health Technology Achievement, Capital's Health Development Research Project.
Abstract (Originalsprache)
PURPOSE: Optimization of urine lipoarabinomannan (LAM) detection platforms holds significant potential for improving early tuberculosis (TB) diagnosis. Currently, accurate urine LAM assays are notably lacking for HIV-negative populations. To address this gap, we evaluated the diagnostic accuracy of an Ultra-sensitive electrochemiluminescence LAM assay (AIMLAM) in HIV-negative individuals with suspected pulmonary TB in Beijing, China. METHODS: In this prospective multicentre study, we enrolled adult (≥ 18 years), presumptive TB patients in Beijing, China. All participants provided sputum samples for smear microscopy, Xpert MTB/RIF assay, and mycobacterial culture, as well as urine samples for AIMLAM testing. Diagnostic performance was evaluated against both microbiological reference standard (MRS) and a composite reference standard (CRS). RESULTS: We collected and stored urine samples from 692 HIV-negative adult presumptive TB patients. Of these, 315 were microbiologically confirmed TB cases, 177 had possible TB, and 200 were considered unlikely to have TB. When evaluated against the MRS, the AIMLAM assay demonstrated a sensitivity of 61.6% (95% CI: 56.1-66.8) and specificity of 83.0% (95% CI: 78.9-86.5). Using the CRS, the AIMLAM assay showed sensitivity 51.6% (95% CI: 47.3-55.9) but specificity 98.0% (95% CI: 94.9-99.4). CONCLUSIONS: The Ultra-sensitive electrochemiluminescence LAM assay demonstrated favorable diagnostic accuracy, potentially offering rapid tuberculosis diagnosis for HIV-negative individuals with pulmonary TB.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Beijing Key Laboratory for Key Technologies in Tuberculosis Prevention and Control, Department of Bacteriology and Immunology, Beijing Chest Hospital, Capital Medical University/Beijing Tuberculosis and Thoracic Tumor R…
- The Second Department of Tuberculosis, Beijing Chest Hospital, Capital Medical University, Beijing, 101149, China.
- Beijing Geriatric Hospital, Beijing, 100095, China.
- Beijing Tsinghua Changing Hospital, Tsinghua University, Beijing, 102200, China.
- The Second Department of Tuberculosis, Beijing Chest Hospital, Capital Medical University, Beijing, 101149, China. 2320652139@qq.com.
Förderung
- Beijing Research Ward Excellence Program
- Beijing Municipal Health and Health Technology Achievement
- Capital's Health Development Research Project
- Capital’s Health Development Research Project
Zitieren
APA
Shang, Y., Zhang, J., Cao, W., Lin, M., Wang, Y., Wang, L., Zhong, L., Wang, X., Hou, W., Xu, W., Wu, G., Wu, J., Pang, Y., & Yang, X. (2026). Performance of ultra-sensitive electrochemiluminescence LAM assay for diagnosing tuberculosis in HIV-negative individuals: a multicentre, prospective diagnostic study. Infection, 54(5), 2437-2445. https://doi.org/10.1007/s15010-026-02861-4
Vancouver
Shang Y, Zhang J, Cao W, Lin M, Wang Y, Wang L, et al. Performance of ultra-sensitive electrochemiluminescence LAM assay for diagnosing tuberculosis in HIV-negative individuals: a multicentre, prospective diagnostic study. Infection. 2026;54(5):2437-2445. doi:10.1007/s15010-026-02861-4
BibTeX
@article{Shang2026,
author = {Shang, Yuanyuan and Zhang, Jiachang and Cao, Wenli and Lin, Mingui and Wang, Yilin and Wang, Lili and Zhong, Leping and Wang, Xiaohui and Hou, Wenjing and Xu, Wei and Wu, Guiping and Wu, Junfeng and Pang, Yu and Yang, Xinting},
title = {Performance of ultra-sensitive electrochemiluminescence LAM assay for diagnosing tuberculosis in HIV-negative individuals: a multicentre, prospective diagnostic study},
journal = {Infection},
year = {2026},
volume = {54},
number = {5},
pages = {2437--2445},
doi = {10.1007/s15010-026-02861-4}
}
EUVIMED