The burden of hospital-acquired legionellosis in German teaching hospitals
Infection · 2026-06 · 54 (3) · 1455-1463
DOI: 10.1007/s15010-026-02782-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Infection, online erschienen am 01.04.2026. Verfasst von Stefanie Kramme und 12 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Infection Prevention and Control, Medical Center, Faculty of Medicine, University of Freiburg, Breisacher Str. 115B, 79014, Freiburg, G…. Hauptthemen laut MEDLINE: Cross Infection, Hospitals, Teaching, Legionnaires' Disease, Legionellosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Freiburg.
Abstract (Originalsprache)
Purpose
Legionella pneumophila is a recognized cause of hospital-acquired pneumonia particularly in immunocompromised patients. Significant resources are dedicated to the monitoring and control of Legionella contamination in hospital water systems. However, the actual risk of nosocomial Legionella infections in German university hospitals, which represent large tertiary care institutions, remains poorly defined. The aim of this study was to quantify the incidence of nosocomial legionellosis in German university hospitals. In addition, the extent of routine testing of hospital drinking water systems and preventive measures implemented on legal grounds was investigated.
Methods
We conducted a retrospective analysis of nosocomial Legionella cases over a five-year period (2020—2024) at the University Medical Center Freiburg (UMCFR), including in-depth genomic typing. We distributed a survey to all 36 German university hospitals to collect data on the incidence of nosocomial infections and prevention strategies. We collected comprehensive data on preventive measures on a regional level among university hospitals in Baden-Württemberg.
Results
Over a five-year period at UMCFR, three patients met the criteria for nosocomial Legionnaires’ disease (LD). In two of these cases, we were able to confirm transmission through the hospital’s drinking water system by genome analysis. Nationwide, 26 of 36 University hospitals reported a total of sixteen cases. All hospitals documented abnormal parametric values (≥ 100 CFU/ml) in their drinking water systems at least once per year. Preventive measures varied widely: the number of sampling points ranged from 30 to 2355, and the number of point-of-use water filters from 30 to 2,200 per hospital. Despite this, incidence of LD remained very low.
Conclusions
Nosocomial Legionella infections are rare in German tertiary care hospitals. However, the impact of intensive prevention measures on the incidence rates of nosocomial Legionella infections remains unclear. Therefore, current practices should be re-evaluated to optimize the use of resources without compromising patient safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Infection Prevention and Control, Medical Center, Faculty of Medicine, University of Freiburg, Breisacher Str. 115B, 79014, Freiburg, Germany.
- Institute for Medical Microbiology and Hygiene, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
- Institute of Medical Microbiology and Hygiene, Tübingen University Hospital, Tübingen, Germany.
- Dept. of Infectious Diseases, Medical Faculty Heidelberg, Medical Microbiology and Hygiene, Heidelberg University, Heidelberg, Germany.
- Department of Hygiene, Medical Faculty Mannheim, Mannheim University Hospital, University of Heidelberg, Mannheim, Germany.
- Institute of Medical Microbiology and Hygiene, Ulm University Hospital, Ulm, Germany.
Förderung
- Universitätsklinikum Freiburg
Zitieren
APA
Kramme, S., Ebner, W., Lösslein, A., Maier, B., Schneider, C., Liese, J., Brandt, C., Heininger, A., von Baum, H., Donker, T., Reuter, S., Henneke, P., & Baden-Württemberg Hospital Infection Prevention Group (BW-HIP) (2026). The burden of hospital-acquired legionellosis in German teaching hospitals. Infection, 54(3), 1455-1463. https://doi.org/10.1007/s15010-026-02782-2
Vancouver
Kramme S, Ebner W, Lösslein A, Maier B, Schneider C, Liese J, et al. The burden of hospital-acquired legionellosis in German teaching hospitals. Infection. 2026;54(3):1455-1463. doi:10.1007/s15010-026-02782-2
BibTeX
@article{Kramme2026,
author = {Kramme, Stefanie and Ebner, Winfried and Lösslein, Anne and Maier, Barbara and Schneider, Christian and Liese, Jan and Brandt, Christian and Heininger, Alexandra and von Baum, Heike and Donker, Tjibbe and Reuter, Sandra and Henneke, Philipp and Baden-Württemberg Hospital Infection Prevention Group (BW-HIP), Baden-Württemberg Hospital Infection Prevention Group (BW-HIP)},
title = {The burden of hospital-acquired legionellosis in German teaching hospitals},
journal = {Infection},
year = {2026},
volume = {54},
number = {3},
pages = {1455--1463},
doi = {10.1007/s15010-026-02782-2}
}
EUVIMED