A systematic review and meta-analysis on diagnostic accuracy of point-of-care C-reactive protein devices for acute respiratory tract infections
Infection · 2026
DOI: 10.1007/s15010-025-02721-7 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Infection, 2026. Verfasst von Rakesh Kumar Sahoo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Health Technology Assessment India (HTAIn), ICMR-Regional Medical Research Centre, Bhubaneswar, 751023, Odisha, India. Hauptthemen laut MEDLINE: C-Reactive Protein, Respiratory Tract Infections, Point-of-Care Systems, Bacterial Infections. Die Arbeit nennt 76 Literaturangaben. Gefördert von: Department of Health Research, India.
Abstract (Originalsprache)
Acute respiratory tract infections (ARTIs) are among the most common reasons for antibiotic prescriptions globally, despite the majority being viral and self-limiting. Because clinical signs alone are often insufficient, there is a clear need for rapid diagnostic methods to support evidence-based prescribing. We assessed the effectiveness of point-of-care C-reactive protein (POCT-CRP) testing devices for distinguishing between bacterial and viral ARTIs. Our search of five databases produced 413 studies, of which 29 met criteria, and six were included in the meta-analysis. The devices with adequate performance data were QuikRead CRP, NycoCard Reader II, and FebriDx®. Overall pooled sensitivity 70% (95% CI 52-83%) and specificity 86% (95% CI 80-91%). The FebriDx showed a pooled sensitivity of 84% (95% CI 76-90%) and specificity of 87% (95% CI 82-91%). The QuikRead showed a pooled sensitivity of 35% (95% CI 30-40%) and specificity of 86% (95% CI 82-89%). The NycoCard Reader II showed a pooled sensitivity of 54% (95% CI 21-83%) and specificity of 86% (95% CI 59-96%). Although POCT-CRP testing is useful in distinguishing between bacterial and viral ARTIs and is critical for antibiotic prescription, further evidence, including cost-effectiveness analysis, is needed to determine whether the implementation of POCT-CRP improves value or merely raises healthcare expenses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Health Technology Assessment India (HTAIn), ICMR-Regional Medical Research Centre, Bhubaneswar, 751023, Odisha, India.
- Department of Health Research, Health Technology Assessment India (HTAIn), Ministry of Health & Family Welfare, Govt. of India, New Delhi, 110001, India. sahookrushna@yahoo.com.
- Department of Health Research, Health Technology Assessment India (HTAIn), Ministry of Health & Family Welfare, Govt. of India, New Delhi, 110001, India.
- South Asian Institute of Health Promotion, Bhubaneswar, Odisha, 751012, India.
- Health Technology Assessment India (HTAIn), ICMR-Regional Medical Research Centre, Bhubaneswar, 751023, Odisha, India. drsanghamitra12@gmail.com.
Förderung
- Department of Health Research, India
Zitieren
APA
Sahoo, R. K., Sahoo, K. C., Sachin, O., Sinha, A., Jena, S., Jena, A., Bhattacharya, D., & Pati, S. (2026). A systematic review and meta-analysis on diagnostic accuracy of point-of-care C-reactive protein devices for acute respiratory tract infections. Infection. https://doi.org/10.1007/s15010-025-02721-7
Vancouver
Sahoo RK, Sahoo KC, Sachin O, Sinha A, Jena S, Jena A, et al. A systematic review and meta-analysis on diagnostic accuracy of point-of-care C-reactive protein devices for acute respiratory tract infections. Infection. 2026. doi:10.1007/s15010-025-02721-7
BibTeX
@article{Sahoo2026,
author = {Sahoo, Rakesh Kumar and Sahoo, Krushna Chandra and Sachin, Oshima and Sinha, Abhinav and Jena, Shubharanjan and Jena, Abhisek and Bhattacharya, Debdutta and Pati, Sanghamitra},
title = {A systematic review and meta-analysis on diagnostic accuracy of point-of-care C-reactive protein devices for acute respiratory tract infections},
journal = {Infection},
year = {2026},
doi = {10.1007/s15010-025-02721-7}
}
EUVIMED