Übersichtsarbeit in der Zeitschrift Biomedical Engineering Letters, online erschienen am 27.02.2026. Verfasst von Yemin Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Hanyang University, Seoul, South Korea. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Bio & Medical Technology Development Program, Institute of Information and Communications Technology Planning and Evaluation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Deep brain stimulation has demonstrated efficacy in treating various neurological disorders. However, its invasiveness and the associated surgical risks have motivated noninvasive approaches that can selectively modulate deep targets. Conventional transcranial electrical stimulation techniques, however, have limited capability to reach deep brain regions with high spatial focality. Temporal interference stimulation (TIS) has emerged as a promising solution to overcome these challenges, using two slightly different high-frequency carriers to generate a low-frequency envelope with improved spatial focality in tissue. Currently, TIS is being extensively validated in rodent models and has been expanded to studies using cadaveric human heads and clinical trials for various neurological disorders. However, the precision and safety of TIS strongly depends on the underlying hardware implementation. Therefore, a systematic understanding of circuit and system design is required for practical device development. This paper covers comprehensive hardware design considerations and implementation strategies for TIS devices. Major TIS waveform schemes are categorized and their impact on system complexity, channel synchronization, and stimulation performance is analyzed. For the output stage architecture, various circuit topologies are discussed regarding their voltage compliance and current driving capability. In addition, essential safety features, including charge balancing techniques and impedance monitoring methods tailored to TIS operation are reviewed. Finally, experimental validation approaches using tissue phantoms are summarized to provide guidelines for developing robust and reliable TIS systems.

Schlagwörter

Stichwörter der Autor:innen

Hardware implementationNeural stimulatorNon-invasive neuromodulationTemporal interference stimulation

Autor:innen und Institutionen

  • Department of Electronic Engineering, Hanyang University, Seoul, South Korea.
  • Department of Artificial Intelligence Semiconductor Engineering, Hanyang University, Seoul, South Korea.

ORCID-Profile: Byunghun Lee

Förderung

  • Bio & Medical Technology Development Program
  • Institute of Information and Communications Technology Planning and Evaluation

Zitieren

APA

Kim, Y., Lee, J., Kil, J., Kim, D., Jeong, T., & Lee, B. (2026). Temporal interference stimulation devices: a comprehensive review of hardware design and implementation. Biomedical Engineering Letters, 16(3), 595-605. https://doi.org/10.1007/s13534-026-00564-1

Vancouver

Kim Y, Lee J, Kil J, Kim D, Jeong T, Lee B. Temporal interference stimulation devices: a comprehensive review of hardware design and implementation. Biomedical Engineering Letters. 2026;16(3):595-605. doi:10.1007/s13534-026-00564-1

BibTeX
@article{Kim2026,
  author = {Kim, Yemin and Lee, Junhyuck and Kil, Jaejun and Kim, Dongrim and Jeong, Taegil and Lee, Byunghun},
  title = {Temporal interference stimulation devices: a comprehensive review of hardware design and implementation},
  journal = {Biomedical Engineering Letters},
  year = {2026},
  volume = {16},
  number = {3},
  pages = {595--605},
  doi = {10.1007/s13534-026-00564-1}
}
Kostenlos starten →