EUVIMEDEUVIMED entdecken
Open Access

Evaluation of consumer-grade wireless EEG systems for brain-computer interface applications

Seungchan Lee, Misung Kim, Minkyu Ahn iD

Biomedical Engineering Letters · 2024-11 · 14 (6) · 1433-1443

DOI: 10.1007/s13534-024-00416-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Engineering Letters, online erschienen am 13.08.2024. Verfasst von Seungchan Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Device, Korea Institute of Machinery & Materials, Daegu, 42994 Republic of Korea. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Research Foundation of Korea, the National Program for Excellence in SW supervised by the IITP.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the growing popularity of consumer-grade electroencephalogram (EEG) devices for health, entertainment, and cognitive research, assessing their signal quality is essential. In this study, we evaluated four consumer-grade wireless and dry-electrode EEG systems widely used for brain-computer interface (BCI) research and applications, comparing them with a research-grade system. We designed an EEG phantom method that reproduced µV-level amplitude EEG signals and evaluated the five devices based on their spectral responses, temporal patterns of event-related potential (ERP), and spectral patterns of resting-state EEG. We discovered that the consumer-grade devices had limited bandwidth compared with the research-grade device. A late component (e.g., P300) was detectable in the consumer-grade devices, but the overall ERP temporal pattern was distorted. Only one device showed an ERP temporal pattern comparable to that of the research-grade device. On the other hand, we confirmed that the activation of the alpha rhythm was observable in all devices. The results provide valuable insights for researchers and developers when it comes to selecting suitable EEG devices for BCI research and applications.

Schlagwörter

Stichwörter der Autor:innen

Brain-computer interfaceConsumer-gradeEEG deviceElectroencephalogramSignal quality

Autor:innen und Institutionen

  • Department of Medical Device, Korea Institute of Machinery & Materials, Daegu, 42994 Republic of Korea.
  • School of Computer Science and Electrical Engineering, Handong Global University, Pohang, 37554 Republic of Korea.

ORCID-Profile: Minkyu Ahn

Förderung

  • National Research Foundation of Korea
  • the National Program for Excellence in SW supervised by the IITP

Zitieren

APA

Lee, S., Kim, M., & Ahn, M. (2024). Evaluation of consumer-grade wireless EEG systems for brain-computer interface applications. Biomedical Engineering Letters, 14(6), 1433-1443. https://doi.org/10.1007/s13534-024-00416-w

Vancouver

Lee S, Kim M, Ahn M. Evaluation of consumer-grade wireless EEG systems for brain-computer interface applications. Biomedical Engineering Letters. 2024;14(6):1433-1443. doi:10.1007/s13534-024-00416-w

BibTeX
@article{Lee2024,
  author = {Lee, Seungchan and Kim, Misung and Ahn, Minkyu},
  title = {Evaluation of consumer-grade wireless EEG systems for brain-computer interface applications},
  journal = {Biomedical Engineering Letters},
  year = {2024},
  volume = {14},
  number = {6},
  pages = {1433--1443},
  doi = {10.1007/s13534-024-00416-w}
}
Kostenlos starten →