EUVIMEDEUVIMED entdecken
Crossref

Trends and incidence of reported events associated with staplers: an analysis of the food and drug administration’s manufacturer and user facility device experience database

Jordi Stira, Riccardo Lombardo, Carmen Gravina, Antonio Cicione, Giorgia Tema, Antonio Nacchia, Andrea Tubaro, Cosimo De Nunzio

Updates in Surgery · 2026-10 · 78 (6) · 2807-2811

DOI: 10.1007/s13304-025-02478-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Updates in Surgery, online erschienen am 19.01.2026. Verfasst von Jordi Stira und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Sapienza Università di Roma, Via di Grottarossa 1089, Rome, Italy. Hauptthemen laut MEDLINE: United States Food and Drug Administration, Databases, Factual, Equipment Failure, Surgical Staplers. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To summarize medical device reports (MDRs) between 2012 and 2022 relating to staplers within the Manufacturer and User Facility Device Experience (MAUDE) database maintained by The Food and Drug Administration (FDA). The MAUDE database was analysed for all MDRs relating to each FDA-approved stapler for the last ten years. Event descriptions were reviewed and characterized into specific event types for all the different manufacturers. All data is de-identified and in compliance with the Health Insurance Portability and Accountability Act (HIPAA). No further data was available in the database. Pooled Relative risk was used to compare data. Overall, 712 reports were retrieved in 10 years. In all, 413/712 (58%) were reported as malfunction of the device while 292/712 (41%) as injury. The most frequently reported adverse events (AEs) were Misfire (111/712: 15.6%), Failure to form staple (92/712: 12.9%), Mechanical jam (76/712: 10.7%) and Failure to fire (72/712: 10.1%). In terms of manufacturer: 401/712 (56%) were Covidien, 172/712 (24%) were Teleflex Medical and 139/712 (19.5%) were Ethicon Instruments. When comparing on disproportional analysis the different manufacturers, Teleflex medical's staplers were safer in terms of failure to fire and failure to form staple and Covidien showed the safest profile for misfire and along with Ethicon for mechanical jam. According to MAUDE database the most frequent complications related to staplers are misfire, failure to form staple, mechanical jam and failure to fire and the reported adverse events vary among the different manufacturers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

United States Food and Drug AdministrationDatabases, FactualEquipment FailureSurgical StaplersUnited StatesHumansIncidence

Stichwörter der Autor:innen

Adverse eventMAUDEMalfunctionMedical deviceSurgical staplers

Autor:innen und Institutionen

  • Department of Urology, Sapienza Università di Roma, Via di Grottarossa 1089, Rome, Italy.
  • Department of Urology, Sapienza Università di Roma, Via di Grottarossa 1089, Rome, Italy. rlombardo@me.com.

Zitieren

APA

Stira, J., Lombardo, R., Gravina, C., Cicione, A., Tema, G., Nacchia, A., Tubaro, A., & De Nunzio, C. (2026). Trends and incidence of reported events associated with staplers: an analysis of the food and drug administration’s manufacturer and user facility device experience database. Updates in Surgery, 78(6), 2807-2811. https://doi.org/10.1007/s13304-025-02478-6

Vancouver

Stira J, Lombardo R, Gravina C, Cicione A, Tema G, Nacchia A, et al. Trends and incidence of reported events associated with staplers: an analysis of the food and drug administration’s manufacturer and user facility device experience database. Updates in Surgery. 2026;78(6):2807-2811. doi:10.1007/s13304-025-02478-6

BibTeX
@article{Stira2026,
  author = {Stira, Jordi and Lombardo, Riccardo and Gravina, Carmen and Cicione, Antonio and Tema, Giorgia and Nacchia, Antonio and Tubaro, Andrea and De Nunzio, Cosimo},
  title = {Trends and incidence of reported events associated with staplers: an analysis of the food and drug administration’s manufacturer and user facility device experience database},
  journal = {Updates in Surgery},
  year = {2026},
  volume = {78},
  number = {6},
  pages = {2807--2811},
  doi = {10.1007/s13304-025-02478-6}
}
Kostenlos starten →