EUVIMEDEUVIMED entdecken
Crossref

Revisiting large complex ventral hernia repair: multimodal hybrid technique deploying preoperative Botulinum Toxin A injection, laparoscopic anterior components separation and open mesh repair

Khawar S Hashmi, Yagazie Zina Udeaja, Jamasp Dastur, Simon Allen, Partha Das

Updates in Surgery · 2024

DOI: 10.1007/s13304-024-01822-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Updates in Surgery, 2024. Verfasst von Khawar S Hashmi und 4 weiteren Autor:innen. Beteiligte Einrichtung: General & Colorectal Surgery Department, Luton & Dunstable University Hospital NHS Trust, Luton, Bedfordshire, UK. khashmi@nhs.net. Hauptthemen laut MEDLINE: Hernia, Ventral, Laparoscopy, Herniorrhaphy, Surgical Mesh. Die Arbeit nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the past, various techniques had been described to repair large complex ventral hernias. Laparoscopic technique of components separation showed low complication rates and better overall outcome. Recently, Botulinum Toxin A (BTA) has shown benefit in achieving tension-free repair. We describe here our multimodal technique combining BTA injection, laparoscopic anterior components separation (LACS) and open mesh repair. Ten consecutive cases performed over 3 years were studied. A standardised technique was used with a reasonably short learning curve. Patients who generally fit for general anaesthesia were offered surgery after detailed preoperative imaging work up and informed consent. Demographic details, preoperative risk stratification, intraoperative and postoperative outcomes were recorded and analysed. A structured step by step management strategy was adopted. Total ten (n = 10) cases with median age of 42.5 years (range 28-76 years), male to female ratio of 8:2 and median BMI of 32.6 were included. Three patients had pre-existing stomas. Median diameter of hernial defect was 10 cm, IQR 4.8 cm and range of 6-20 cm. No intraoperative or immediate complications were observed. Median hospital stay was 6 days. Two seromas (20%) and two return to theatre (20%) were observed. One recurrence (10%) was observed after median follow-up of 32 months. No 90-day mortality was recorded. Multimodal technique of BTA injection, LACS and midline mesh repair is a reproducible, safe and effective option to repair large complex ventral hernias.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hernia, VentralLaparoscopyHerniorrhaphySurgical MeshBotulinum Toxins, Type AHumansFemaleMaleMiddle AgedAdultAgedTreatment OutcomePreoperative CareCombined Modality Therapy

Stichwörter der Autor:innen

Components separationHerniaIntraperitoneal meshLaparoscopicVentral hernia

Substanzen

Botulinum Toxins, Type A

Autor:innen und Institutionen

  • General & Colorectal Surgery Department, Luton & Dunstable University Hospital NHS Trust, Luton, Bedfordshire, UK. khashmi@nhs.net.
  • General & Colorectal Surgery Department, Luton & Dunstable University Hospital NHS Trust, Luton, Bedfordshire, UK.
  • Department of Interventional Radiology, Luton & Dunstable University Hospital NHS Trust, Luton, Bedfordshire, UK.

Zitieren

APA

Hashmi, K. S., Udeaja, Y. Z., Dastur, J., Allen, S., & Das, P. (2024). Revisiting large complex ventral hernia repair: multimodal hybrid technique deploying preoperative Botulinum Toxin A injection, laparoscopic anterior components separation and open mesh repair. Updates in Surgery. https://doi.org/10.1007/s13304-024-01822-6

Vancouver

Hashmi KS, Udeaja YZ, Dastur J, Allen S, Das P. Revisiting large complex ventral hernia repair: multimodal hybrid technique deploying preoperative Botulinum Toxin A injection, laparoscopic anterior components separation and open mesh repair. Updates in Surgery. 2024. doi:10.1007/s13304-024-01822-6

BibTeX
@article{Hashmi2024,
  author = {Hashmi, Khawar S and Udeaja, Yagazie Zina and Dastur, Jamasp and Allen, Simon and Das, Partha},
  title = {Revisiting large complex ventral hernia repair: multimodal hybrid technique deploying preoperative Botulinum Toxin A injection, laparoscopic anterior components separation and open mesh repair},
  journal = {Updates in Surgery},
  year = {2024},
  doi = {10.1007/s13304-024-01822-6}
}
Kostenlos starten →