EUVIMEDEUVIMED entdecken
Crossref

Distinguishing model- and environment-related effects in knowledge-based planning of moderately hypofractionated prostate VMAT

Yuto Yamaji, Motoharu Sasaki iD, Yuji Nakaguchi, Takeshi Kamomae, Yuki Kanazawa, Kanako Sakuragawa, Ryosuke Kasai, Yuki Tominaga, Hitoshi Ikushima

Physical and Engineering Sciences in Medicine · 2026

DOI: 10.1007/s13246-026-01778-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2026. Verfasst von Yuto Yamaji und 8 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Health Sciences, Tokushima University, 3-18-15 Kuramoto-cho, Tokushima, Tokushima, 770-8503, Japan. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Environment. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Knowledge-based planning (KBP) can improve the efficiency and consistency of volumetric-modulated arc therapy (VMAT); however, the extent to which treatment-machine characteristics influence KBP model behavior remains unclear. This study aimed to clarify the dosimetric impact of machine-specific KBP models by distinguishing the contributions of model libraries and plan-generation environment. Three RapidPlan models were independently trained using 30 manually generated plans created on NovalisTx (15X), TrueBeam (10X), and Halcyon (6FFF). The models were applied to an independent cohort of 15 patients using two complementary evaluation approaches: a clinical evaluation employing each machine’s native beam model and a controlled evaluation using a common TrueBeam 10X beam model with identical optimization settings. Dosimetric endpoints included planning target volume excluding the rectum (PTV-R) D2% and D98%, rectal V31/V46/V54/V58 Gy, and bladder V31/V50 Gy. In the library plans, significant differences were observed for the PTV-R metrics, rectal V54/V58 Gy, and bladder V50 Gy. Under clinical conditions, significant differences remained for the PTV-R D2% and D98% and for bladder V50 Gy, whereas rectal indices showed no significant differences. Under controlled conditions, differences in PTV-R and rectal metrics were no longer significant, whereas bladder V31 Gy and V50 Gy remained significantly different. These findings suggest that the impact of machine-specific KBP models is endpoint-dependent and reflect the combined influence of model-derived objectives and the plan-generation environment. Standardization of beam modeling and optimization conditions reduced inter-model differences for target and rectal metrics, whereas bladder-related differences persisted, indicating that KBP model management in multi-machine environments should consider endpoint-dependent behavior.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsRadiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedEnvironmentRadiation Dose HypofractionationKnowledge BasesHumansMale

Stichwörter der Autor:innen

Knowledge-based planningMachine-specific modelsPlan-generation environmentProstate cancerVMAT

Autor:innen und Institutionen

  • Graduate School of Health Sciences, Tokushima University, 3-18-15 Kuramoto-cho, Tokushima, Tokushima, 770-8503, Japan.
  • Graduate School of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto- cho, Tokushima, Tokushima, 770-8503, Japan. msasaki@tokushima-u.ac.jp.
  • Toyo-Medic Co, Ltd. 3-8-5 Iidabashi, Chiyoda-ku, Tokyo, 102-0072, Japan.
  • Medical Branch, Radioisotope Research Center, Nagoya University, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi, 466-8550, Japan.
  • Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi, 466-8550, Japan.
  • Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Chuo-ku, Kumamoto, 862-0976, Japan.

ORCID-Profile: Motoharu Sasaki

Zitieren

APA

Yamaji, Y., Sasaki, M., Nakaguchi, Y., Kamomae, T., Kanazawa, Y., Sakuragawa, K., Kasai, R., Tominaga, Y., & Ikushima, H. (2026). Distinguishing model- and environment-related effects in knowledge-based planning of moderately hypofractionated prostate VMAT. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-026-01778-4

Vancouver

Yamaji Y, Sasaki M, Nakaguchi Y, Kamomae T, Kanazawa Y, Sakuragawa K, et al. Distinguishing model- and environment-related effects in knowledge-based planning of moderately hypofractionated prostate VMAT. Physical and Engineering Sciences in Medicine. 2026. doi:10.1007/s13246-026-01778-4

BibTeX
@article{Yamaji2026,
  author = {Yamaji, Yuto and Sasaki, Motoharu and Nakaguchi, Yuji and Kamomae, Takeshi and Kanazawa, Yuki and Sakuragawa, Kanako and Kasai, Ryosuke and Tominaga, Yuki and Ikushima, Hitoshi},
  title = {Distinguishing model- and environment-related effects in knowledge-based planning of moderately hypofractionated prostate VMAT},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2026},
  doi = {10.1007/s13246-026-01778-4}
}
Kostenlos starten →