Biomechanics-driven dose stress metrics for radiation-induced acute xerostomia prediction among head and neck radiation therapy
Physical and Engineering Sciences in Medicine · 2025
DOI: 10.1007/s13246-025-01558-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2025. Verfasst von Yusuke Kawazoe und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Yamaguchi University Hospital, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8535, Japan. Hauptthemen laut MEDLINE: Xerostomia, Head and Neck Neoplasms, Stress, Mechanical. Die Arbeit nennt 46 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Takeda Science Foundation.
Abstract (Originalsprache)
Xerostomia is a condition commonly affecting patients subjected to radiation therapy (RT) for head and neck cancer (HNC) treatment. We propose dose metrics that consider the stress of parotid glands (PGs) during RT by using finite element analysis (FEA) of structural changes captured via computed tomography (CT) images acquired before and during RT to evaluate their effectiveness in predicting acute xerostomia. Thirty patients treated for HNC via in volumetric modulated arc therapy were enrolled. Patient complaints were considered by radiation oncologists based on the common terminology criteria for adverse events and scored as xerostomia grade 0 (XG-0), XG-1, or XG-2. All patients underwent CT both before and during RT (CTini and CTbst, respectively). FE-based deformable image registration was performed from the CTini images to the CTbst images, following which the stress of PGs was calculated and generate the dose-stress histograms (DSH). Four classical indices (volume change, mean dose, CT value change in PGs, and weight change), the mean stress, dose-volume histogram (DVH), and DSH metrics were used to evaluate the effectiveness of our approach. No significant differences among patients w/wo acute xerostomia groups were noted based on the four classical indices, mean stress, or DVH metrics; however, DSH metrics presented significant differences (p 0.70). The proposed metrics can analyze stress values without additional examinations and demonstrate significant differences between groups w/wo acute xerostomia and between different XGs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiological Technology, Yamaguchi University Hospital, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8535, Japan.
- Department of Radiation Oncology, Graduate School of Medicine, Yamaguchi University, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8535, Japan. shiinoki@yamaguchi-u.ac.jp.
- Department of Radiation Oncology, Graduate School of Medicine, Yamaguchi University, 1-1-1 Minamikogushi, Ube, Yamaguchi, 755-8535, Japan.
Förderung
- Japan Society for the Promotion of Science
- Takeda Science Foundation
Zitieren
APA
Kawazoe, Y., Shiinoki, T., Fujimoto, K., Yuasa, Y., Mukaidani, W., Manabe, Y., Kajima, M., & Tanaka, H. (2025). Biomechanics-driven dose stress metrics for radiation-induced acute xerostomia prediction among head and neck radiation therapy. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-025-01558-6
Vancouver
Kawazoe Y, Shiinoki T, Fujimoto K, Yuasa Y, Mukaidani W, Manabe Y, et al. Biomechanics-driven dose stress metrics for radiation-induced acute xerostomia prediction among head and neck radiation therapy. Physical and Engineering Sciences in Medicine. 2025. doi:10.1007/s13246-025-01558-6
BibTeX
@article{Kawazoe2025,
author = {Kawazoe, Yusuke and Shiinoki, Takehiro and Fujimoto, Koya and Yuasa, Yuki and Mukaidani, Wataru and Manabe, Yuki and Kajima, Miki and Tanaka, Hidekazu},
title = {Biomechanics-driven dose stress metrics for radiation-induced acute xerostomia prediction among head and neck radiation therapy},
journal = {Physical and Engineering Sciences in Medicine},
year = {2025},
doi = {10.1007/s13246-025-01558-6}
}
EUVIMED