Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters
Physical and Engineering Sciences in Medicine · 2024
DOI: 10.1007/s13246-024-01463-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Marziyeh Mirzaeiyan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Radiotherapy Dosage, Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Isfahan University of Medical Sciences.
Themen: Onkologische Pflege
Abstract (Originalsprache)
The stability of dosiomics features (DFs) and dose-volume histogram (DVH) parameters for detecting disparities in helical tomotherapy planned dose distributions was assessed. Treatment plans of 18 prostate patients were recalculated using the followings: field width (WF) (2.5 vs. 5), pitch factor (PF) (0.433 vs. 0.444), and modulation factor (MF) (2.5 vs. 3). From each of the eight plans per patient, ninety-three original and 744 wavelet-based DFs were extracted, using 3D-Slicer software, across six regions including: target volume (PTV), pelvic lymph nodes (PTV-LN), PTV + PTV-LN (PTV-All), one cm rind around PTV-All (PTV-Ring), rectum, and bladder. For the resulting DFs and DVH parameters, the coefficient of variation (CV) was calculated, and using hierarchical clustering, the features were classified into low/high variability. The significance of parameters on instability was analyzed by a three-way analysis of variance. All DF's were stable in PTV, PTV-LN, and PTV-Ring (average CV ( CV ¯ ) ≤ 0.36). Only one feature in the bladder ( CV ¯ = 0.9), rectum ( CV ¯ = 0.4), and PTV-All ( CV ¯ = 0.37) were considered unstable due to change in MF in the bladder and WF in the PTV-All. The value of CV ¯ for the wavelet features was much higher than that for the original features. Out of 225 unstable wavelet features, 84 features had CV ¯ ≥ 1. The CVs for all the DVHs remained very small ( CV ¯ < 0.06). This study highlights that the sensitivity of DFs to changes in tomotherapy planning parameters is influenced by the region and the DFs, particularly wavelet features, surpassing the effectiveness of DVHs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
- Department of Medical Physics, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran.
- Department of Radiotherapy Oncology, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
- Isfahan Milad Hospital, Isfahan, Iran.
- Department of Radiology, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
- Department of Genetics and Molecular Biology, Faculty of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Förderung
- Isfahan University of Medical Sciences
Zitieren
APA
Mirzaeiyan, M., Akhavan, A., Hemati, S., Etehadtavakol, M., Amouheidari, A., Adibi, A., Khanahmad, H., Sharifonnasabi, Z., & Shokrani, P. (2024). Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01463-4
Vancouver
Mirzaeiyan M, Akhavan A, Hemati S, Etehadtavakol M, Amouheidari A, Adibi A, et al. Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01463-4
BibTeX
@article{Mirzaeiyan2024,
author = {Mirzaeiyan, Marziyeh and Akhavan, Ali and Hemati, Simin and Etehadtavakol, Mahnaz and Amouheidari, Alireza and Adibi, Atoosa and Khanahmad, Hossein and Sharifonnasabi, Zahra and Shokrani, Parvaneh},
title = {Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters},
journal = {Physical and Engineering Sciences in Medicine},
year = {2024},
doi = {10.1007/s13246-024-01463-4}
}
EUVIMED