EUVIMEDEUVIMED entdecken
Crossref

Assessing tumor volumetric reduction with consideration for setup errors based on mathematical tumor model and microdosimetric kinetic model in single-isocenter VMAT for brain metastases

Hisashi Nakano, Takehiro Shiinoki, Satoshi Tanabe, Satoru Utsunomiya, Motoki Kaidu, Teiji Nishio, Hiroyuki Ishikawa

Physical and Engineering Sciences in Medicine · 2024

DOI: 10.1007/s13246-024-01451-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Hisashi Nakano und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan. nakano…. Hauptthemen laut MEDLINE: Brain Neoplasms, Tumor Burden, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The volumetric reduction rate (VRR) was evaluated with consideration for six degrees-of-freedom (6DoF) patient setup errors based on a mathematical tumor model in single-isocenter volumetric modulated arc therapy (SI-VMAT) for brain metastases. Simulated gross tumor volumes (GTV) of 1.0 cm and dose distribution were created (27 Gy/3 fractions). The distance between the GTV center and isocenter (d) was set at 0-10 cm. The GTV was translated within 0-1.0 mm (Trans) and rotated within 0-1.0° (Rot) in the three axis directions using affine transformation. The tumor growth volume was calculated using a multicomponent mathematical model (MCTM), and lethal effects of irradiation and repair from damage during irradiation were calculated by a microdosimetric kinetic model (MKM) for non-small cell lung cancer (NSCLC) A549 and NCI-H460 (H460) cells. The VRRs were calculated 5 days after the end of irradiation using the physical dose to the GTV for varying d and 6DoF setup errors. The tolerance value of VRR, the GTV volume reduction rate, was set at 5%, based on the pre-irradiation GTV volume. With the exception of the only one A549 condition where (Trans, Rot) = (1.0 mm, 1.0°) was repeated for 3 fractions, all conditions met all the tolerance VRR values for A549 and H460 cells with varying d from 0 to 10 cm. Evaluation based on the mathematical tumor model suggested that if the 6DoF setup errors at each irradiation could be kept within 1.0 mm and 1.0°, there would be little effect on tumor volume regardless of the distance from the isocenter in SI-VMAT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain NeoplasmsTumor BurdenRadiotherapy, Intensity-ModulatedHumansKineticsCell Line, TumorModels, BiologicalLung NeoplasmsRadiotherapy Setup ErrorsRadiotherapy Planning, Computer-AssistedRadiometryRadiotherapy Dosage

Stichwörter der Autor:innen

Brain metastasesMathematical modelSetup errorSingle-isocenter techniqueStereotactic radiotherapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan. nakanoh@med.niigata-u.ac.jp.
  • Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan. nakanoh@med.niigata-u.ac.jp.
  • Department of Radiation Oncology, Yamaguchi University, Minamikogushi 1-1-1 Ube, Yamaguchi, Japan.
  • Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan.
  • Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan.
  • Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Nakano, H., Shiinoki, T., Tanabe, S., Utsunomiya, S., Kaidu, M., Nishio, T., & Ishikawa, H. (2024). Assessing tumor volumetric reduction with consideration for setup errors based on mathematical tumor model and microdosimetric kinetic model in single-isocenter VMAT for brain metastases. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01451-8

Vancouver

Nakano H, Shiinoki T, Tanabe S, Utsunomiya S, Kaidu M, Nishio T, et al. Assessing tumor volumetric reduction with consideration for setup errors based on mathematical tumor model and microdosimetric kinetic model in single-isocenter VMAT for brain metastases. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01451-8

BibTeX
@article{Nakano2024,
  author = {Nakano, Hisashi and Shiinoki, Takehiro and Tanabe, Satoshi and Utsunomiya, Satoru and Kaidu, Motoki and Nishio, Teiji and Ishikawa, Hiroyuki},
  title = {Assessing tumor volumetric reduction with consideration for setup errors based on mathematical tumor model and microdosimetric kinetic model in single-isocenter VMAT for brain metastases},
  journal = {Physical and Engineering Sciences in Medicine},
  year = {2024},
  doi = {10.1007/s13246-024-01451-8}
}
Kostenlos starten →