Fachartikel in der Zeitschrift Physical and Engineering Sciences in Medicine, 2024. Verfasst von Palak Handa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of ECE, DTU, New Delhi, India. palakhanda_2k21phdec05@dtu.ac.in. Hauptthemen laut MEDLINE: Capsule Endoscopy. Die Arbeit nennt 32 Literaturangaben. Gefördert von: DST SERB.
Abstract (Originalsprache)
An automated scoring system for cleanliness assessment during video capsule endoscopy (VCE) is presently lacking. The present study focused on developing an approach to automatically assess the cleanliness in VCE frames as per the latest scoring i.e., Korea-Canada (KODA). Initially, an easy-to-use mobile application called artificial intelligence-KODA (AI-KODA) score was developed to collect a multi-label image dataset of twenty-eight patient capsule videos. Three readers (gastroenterology fellows), who had been trained in reading VCE, rated this dataset in a duplicate manner. The labels were saved automatically in real-time. Inter-rater and intra-rater reliability were checked. The developed dataset was then randomly split into train:validate:test ratio of 70:20:10 and 60:20:20. It was followed by a comprehensive benchmarking and evaluation of three multi-label classification tasks using ten machine learning and two deep learning algorithms. Reliability estimation was found to be overall good among the three readers. Overall, random forest classifier achieved the best evaluation metrics, followed by Adaboost, KNeighbours, and Gaussian naive bayes in the machine learning-based classification tasks. Deep learning algorithms outperformed the machine learning-based classification tasks for only VM labels. Thorough analysis indicates that the proposed approach has the potential to save time in cleanliness assessment and is user-friendly for research and clinical use. Further research is required for the improvement of intra-rater reliability of KODA, and the development of automated multi-task classification in this field.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of ECE, DTU, New Delhi, India. palakhanda_2k21phdec05@dtu.ac.in.
- Department of ECE, IGDTUW, New Delhi, India.
- Department of ECE, DTU, New Delhi, India.
- Department of Gastroenterology and HNU, AIIMS, Delhi, India.
Förderung
- DST SERB
Zitieren
APA
Handa, P., Goel, N., Indu, S., & Gunjan, D. (2024). A multi-label dataset and its evaluation for automated scoring system for cleanliness assessment in video capsule endoscopy. Physical and Engineering Sciences in Medicine. https://doi.org/10.1007/s13246-024-01441-w
Vancouver
Handa P, Goel N, Indu S, Gunjan D. A multi-label dataset and its evaluation for automated scoring system for cleanliness assessment in video capsule endoscopy. Physical and Engineering Sciences in Medicine. 2024. doi:10.1007/s13246-024-01441-w
BibTeX
@article{Handa2024,
author = {Handa, Palak and Goel, Nidhi and Indu, S and Gunjan, Deepak},
title = {A multi-label dataset and its evaluation for automated scoring system for cleanliness assessment in video capsule endoscopy},
journal = {Physical and Engineering Sciences in Medicine},
year = {2024},
doi = {10.1007/s13246-024-01441-w}
}
EUVIMED