Measurements of in-air spot size of pencil proton beam for various air gaps in conjunction with a range shifter on a ProteusPLUS PBS dedicated machine and comparison to the proton dose calculation algorithms

Suresh Rana, E James Jebaseelan Samuel

Australasian Physical & Engineering Sciences in Medicine · 2019-09 · 42 (3) · 853-862

DOI: 10.1007/s13246-019-00772-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Australasian Physical & Engineering Sciences in Medicine, online erschienen am 20.06.2019. Verfasst von Suresh Rana und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N Kendall Drive, Miami, FL, 33176, USA. suresh.rana@gmai…. Hauptthemen laut MEDLINE: Air, Algorithms, Proton Therapy, Protons. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of this study is to (i) investigate the impact of various air gaps in conjunction with a range shifter of 7.5 cm water-equivalent-thickness (WET) on in-air spot size of a pencil proton beam at the isocenter and off-axis points, and (ii) compare the treatment planning system (TPS) calculated spot sizes against the measured spot sizes. A scintillation detector has been utilized to measure the in-air spot sizes at the isocenter. The air gap was varied from 0 to 35 cm at an increment of 5 cm. For each air gap, a single spot pencil proton beam of various energies (110-225 MeV) was delivered to the scintillation detector. By mimicking the experimental setup in RayStation TPS, proton dose calculations were performed using pencil beam (RS-PB) and Monte Carlo (RS-MC) dose calculation algorithms. The calculated spot sizes (RS-PB and RS-MC) were then compared against the measured spot sizes. For a comparative purpose, the spot sizes of each measured energy for different air gaps of (5-35 cm) were compared against that of 0 cm air gap. The results of the 5 cm air gap showed an increase in spot size by ≤ 0.6 mm for all energies. For the largest air gap (35 cm) in the current study, the spot size increased by 3.0 mm for the highest energy (225 MeV) and by 9.2 mm for the lowest energy (110 MeV). For the 0 cm air gap, the agreement between the TPS-calculated (RS-PB and RS-MC) and measured spot sizes were within ± 0.1 mm. For the 35 cm air gap, the RS-PB overpredicted spot sizes by 0.3-0.8 mm, whereas the RS-MC computed spot sizes were within ± 0.3 mm of measured spot sizes. In conclusion, spot size increment is dependent on the energy and air gap. The increase in spot size was more pronounced at lower energies ( < 150 MeV) for all air gaps. The comparison between the TPS calculated and measured spot sizes showed that the RS-MC is more accurate (within ± 0.3 mm), whereas the RS-PB overpredicted (up to 0.8 mm) the spot sizes when a range shifter (7.5 cm WET) and large air gaps are encountered in the proton beam path.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AirAlgorithmsProton TherapyProtonsDose-Response Relationship, RadiationRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

Air gapDose calculation algorithmsPencil beam scanning proton therapyRange shifterSpot size

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N Kendall Drive, Miami, FL, 33176, USA. suresh.rana@gmail.com.
  • Department of Radiation Oncology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL, 33199, USA. suresh.rana@gmail.com.
  • Department of Physics, School of Advanced Sciences, Vellore Institute of Technology (VIT) University, Vellore, Tamil Nadu, India. suresh.rana@gmail.com.
  • Department of Physics, School of Advanced Sciences, Vellore Institute of Technology (VIT) University, Vellore, Tamil Nadu, India.

Zitieren

APA

Rana, S., & Samuel, E. J. J. (2019). Measurements of in-air spot size of pencil proton beam for various air gaps in conjunction with a range shifter on a ProteusPLUS PBS dedicated machine and comparison to the proton dose calculation algorithms. Australasian Physical & Engineering Sciences in Medicine, 42(3), 853-862. https://doi.org/10.1007/s13246-019-00772-3

Vancouver

Rana S, Samuel EJJ. Measurements of in-air spot size of pencil proton beam for various air gaps in conjunction with a range shifter on a ProteusPLUS PBS dedicated machine and comparison to the proton dose calculation algorithms. Australasian Physical & Engineering Sciences in Medicine. 2019;42(3):853-862. doi:10.1007/s13246-019-00772-3

BibTeX
@article{Rana2019,
  author = {Rana, Suresh and Samuel, E James Jebaseelan},
  title = {Measurements of in-air spot size of pencil proton beam for various air gaps in conjunction with a range shifter on a ProteusPLUS PBS dedicated machine and comparison to the proton dose calculation algorithms},
  journal = {Australasian Physical & Engineering Sciences in Medicine},
  year = {2019},
  volume = {42},
  number = {3},
  pages = {853--862},
  doi = {10.1007/s13246-019-00772-3}
}
Kostenlos starten →