EUVIMEDEUVIMED entdecken
Crossref

Impact of Implantation Site and Bioprosthetic Valve Type on Valve Failure: Analysis of Explanted Valves from Chinese Patients

Xiaolan Tang, Wentao Feng, Haibo Zhang, Li Li, Guangpu Fan, Hongyue Wang, Xuejing Duan, Wei Zhai, Hui Zuo, Yubo Fan

Cardiovascular Engineering and Technology · 16.11.2026

DOI: 10.1007/s13239-026-00870-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, online erschienen am 16.11.2026. Verfasst von Xiaolan Tang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Adv…. Die Arbeit nennt 45 Literaturangaben. Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, Beijing Science and Technology Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Analysis of explanted bioprosthetic heart valves reveals causes of valve failure. While explant studies are common, factors driving rapid valve deterioration remain unclear. Moreover, long-term valve durability is biomechanically influenced. Understanding how implantation site and bioprosthetic valve type biomechanically affect failure modes is crucial to optimizing valve design and longevity.

Methods

121 failed bioprostheses were explanted from Chinese patients aged 5 to 78 years. Patient and valve data were collected. Failure characteristics and rapid-deterioration characteristics were examined and analyzed. Influences of implantation site (aortic vs. mitral) and bioprosthetic valve type (porcine aortic valve vs. bovine pericardial valve) on failure were statistically assessed.

Results

Younger patients exhibited comparable or exceeding implantation durations versus older patients (age ≤ 40 at implant: 121 ± 60 months vs. age > 40: 95 ± 46 months, p = 0.019). Compared to the group with bioprosthetic in-vivo durability > 5 years, vegetation significantly contributed to rapid failure (>5 years: 9% vs. ≤ 5 years: 45%, p < 0.001). Porcine aortic valves and valves in mitral sites (higher diastolic pressure) showed susceptibility to commissural dehiscence or tears. Calcification distribution correlated positively with high-stress regions. Pannus overgrowth, influenced by hemodynamics, was more prevalent on inflow surfaces (higher flow velocity) than outflow surfaces (98% vs. 67%, p < 0.001).

Conclusions

Biomechanical differences in implantation site and bioprosthetic valve type significantly impact valve failure characteristics, which should be considered in future valve improvements and clinical selection strategies. Moreover, we found that rapidly and gradually failed bioprostheses exhibited distinct failure characteristics; valve durability was not reduced in younger patients.

Schlagwörter

Stichwörter der Autor:innen

Bioprosthetic valve typeExplanted bioprostheses analysisImplantation siteProsthetic heart valvesRapidly bioprosthetic failure

Autor:innen und Institutionen

  • Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology…
  • Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
  • Department of Pathology, Fuwai Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China.
  • Department of Cardiac Surgery, Peking University People's Hospital, Beijing, China.
  • Beijing Center for ADR Monitoring, Beijing, China.

Förderung

  • National Key R&D Program of China
  • National Natural Science Foundation of China
  • Beijing Science and Technology Program
  • the 111 project

Zitieren

APA

Tang, X., Feng, W., Zhang, H., Li, L., Fan, G., Wang, H., Duan, X., Zhai, W., Zuo, H., & Fan, Y. (2026). Impact of Implantation Site and Bioprosthetic Valve Type on Valve Failure: Analysis of Explanted Valves from Chinese Patients. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-026-00870-w

Vancouver

Tang X, Feng W, Zhang H, Li L, Fan G, Wang H, et al. Impact of Implantation Site and Bioprosthetic Valve Type on Valve Failure: Analysis of Explanted Valves from Chinese Patients. Cardiovascular Engineering and Technology. 2026. doi:10.1007/s13239-026-00870-w

BibTeX
@article{Tang2026,
  author = {Tang, Xiaolan and Feng, Wentao and Zhang, Haibo and Li, Li and Fan, Guangpu and Wang, Hongyue and Duan, Xuejing and Zhai, Wei and Zuo, Hui and Fan, Yubo},
  title = {Impact of Implantation Site and Bioprosthetic Valve Type on Valve Failure: Analysis of Explanted Valves from Chinese Patients},
  journal = {Cardiovascular Engineering and Technology},
  year = {2026},
  doi = {10.1007/s13239-026-00870-w}
}
Kostenlos starten →