Reducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study
Cardiovascular Engineering and Technology · 2026-10 · 17 (5) · 591-600
DOI: 10.1007/s13239-026-00848-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, online erschienen am 07.07.2026. Verfasst von Lisa Rutten und 6 weiteren Autor:innen. Beteiligte Einrichtung: Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Hallenweg 5, 7522 NH, Enschede, The Netherlands. lisarutten4@gmail.com. Hauptthemen laut MEDLINE: Stents, Femoral Artery, Artifacts, Phantoms, Imaging. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Holland High Tech with Public-Private-Partnership (PPP) allowance for research and development in the top sector High Tech Systems and Materials.
Abstract (Originalsprache)
Purpose
Spectral computed tomography derived virtual monoenergetic imaging (VMI) reconstructions have been shown to reduce stent-induced blooming artifacts thus minimizing in-stent lumen underestimation. We have investigated the use of VMI reconstructions to reduce the blooming artifact for stent markers, single and double stent configurations.
Methods
Two partially overlapping covered stents were deployed in a superficial femoral artery phantom. A conventional and twelve VMI reconstructions (40–100 keV and 120–200 keV with 10 and 20 keV increments, respectively) were created. Contrast-to-noise ratio, signal-to-noise ratio, attenuation difference between native and in-stent vessel lumen and full width at half maximum (FWHM) of the stent peaks were evaluated. The in-stent lumen diameter was measured, and the stent evaluated using a 5-point scale by three interventional radiologists.
Results
The 80–100 keV VMI reconstructions for the single stent configuration and the 140 keV VMI reconstruction for the other configurations resulted in the smallest lumen underestimation and best quality score on blooming. The underestimation was reduced from 21.5–29.1% for the conventional reconstruction to 14.1–18.6% for the optimal VMI reconstructions. No significant differences were observed in FWHM between the conventional reconstruction and the 50–200 keV VMI reconstructions.
Conclusions
VMI was found to minimize stent-induced blooming artifacts and improve in-stent lumen assessment. More stent material requires higher-energy VMI reconstructions to reduce blooming. The absence of significant differences in quantitative parameters suggests that the number of pixels affected by the blooming artifact is not reduced using VMI reconstructions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Hallenweg 5, 7522 NH, Enschede, The Netherlands. lisarutten4@gmail.com.
- Department of Surgery, Rijnstate, Arnhem, The Netherlands. lisarutten4@gmail.com.
- Physics of Fluids group, TechMed Centre, University of Twente, Enschede, The Netherlands. lisarutten4@gmail.com.
- Department of Thermal and Fluid Engineering, University of Twente, Enschede, The Netherlands. lisarutten4@gmail.com.
- Multi-Modality Medical Imaging Group, TechMed Centre, University of Twente, Hallenweg 5, 7522 NH, Enschede, The Netherlands.
- Department of Surgery, Rijnstate, Arnhem, The Netherlands.
Förderung
- Holland High Tech with Public-Private-Partnership (PPP) allowance for research and development in the top sector High Tech Systems and Materials
Zitieren
APA
Rutten, L., van de Velde, L., Slump, C. H., Martens, J., Jain, K., Versluis, M., & Reijnen, M. M. P. J. (2026). Reducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study. Cardiovascular Engineering and Technology, 17(5), 591-600. https://doi.org/10.1007/s13239-026-00848-8
Vancouver
Rutten L, van de Velde L, Slump CH, Martens J, Jain K, Versluis M, et al. Reducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study. Cardiovascular Engineering and Technology. 2026;17(5):591-600. doi:10.1007/s13239-026-00848-8
BibTeX
@article{Rutten2026,
author = {Rutten, Lisa and van de Velde, Lennart and Slump, Cornelis H and Martens, Jasper and Jain, Kartik and Versluis, Michel and Reijnen, Michel M P J},
title = {Reducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study},
journal = {Cardiovascular Engineering and Technology},
year = {2026},
volume = {17},
number = {5},
pages = {591--600},
doi = {10.1007/s13239-026-00848-8}
}
EUVIMED