EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Auxetic Stents as a Next Generation Solution for Vascular Diseases–A Review

Khanish Gupta, Kusum Meena, S H Chandrashekhara

Cardiovascular Engineering and Technology · 2026-10 · 17 (5) · 654-673

DOI: 10.1007/s13239-026-00846-w ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Cardiovascular Engineering and Technology, online erschienen am 22.06.2026. Verfasst von Khanish Gupta und 2 weiteren Autor:innen. Beteiligte Einrichtung: Indian Institute of Technology Delhi, New Delhi, India. Hauptthemen laut MEDLINE: Stents, Endovascular Procedures, Vascular Diseases. Die Arbeit nennt 184 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Vascular diseases, particularly atherosclerosis, represent a leading cause of global morbidity and mortality. Endovascular stenting has emerged as a cornerstone of therapy to restore vessel patency, yet conventional stents remain obstructed by significant clinical limitations, including in-stent restenosis, thrombosis, and mechanical failure. These adverse outcomes are intrinsically linked to their fundamental structural design, which is characterized by a positive Poisson’s ratio, leading to foreshortening and a biomechanical mismatch with the native vasculature.

Methods

This review critically examines auxetic stents as a next-generation solution, engineered with a structure possessing a negative Poisson’s ratio. This unique property allows them to expand axially upon radial deployment, thereby eliminating foreshortening, enhancing conformability to tortuous vessels, and distributing mechanical stress more uniformly onto the arterial wall.

Results

This paper synthesizes the robust body of in-silico/bench-top evidence from computational modeling and in-vitro experimentation that validates these superior biomechanical characteristics. Furthermore, it explores the profound and favorable biological implications, arguing that the optimized mechanical environment and improved hemodynamics are hypothesized to attenuate the primary triggers for neointimal hyperplasia and foster rapid, complete endothelialization.

Conclusion

The review concludes by outlining the translational pathway, including challenges in structure integration and discussing the vast future horizons for auxetic structured stents in complex peripheral, carotid, and non-vascular applications. Auxetic design represents a paradigm shift from material-centric iteration to structure-driven innovation, holding the promise to significantly improve the long-term safety and efficacy of endovascular stent implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StentsEndovascular ProceduresVascular DiseasesHumansProsthesis DesignAnimalsHemodynamicsTreatment OutcomeStress, Mechanical

Stichwörter der Autor:innen

AtherosclerosisAuxeticImplantStentVascular disease

Autor:innen und Institutionen

  • Indian Institute of Technology Delhi, New Delhi, India.
  • Indian Institute of Technology Delhi, New Delhi, India. kusum@iitd.ac.in.
  • All India Institute of Medical Sciences Delhi, New Delhi, India.

Zitieren

APA

Gupta, K., Meena, K., & Chandrashekhara, S. H. (2026). Auxetic Stents as a Next Generation Solution for Vascular Diseases–A Review. Cardiovascular Engineering and Technology, 17(5), 654-673. https://doi.org/10.1007/s13239-026-00846-w

Vancouver

Gupta K, Meena K, Chandrashekhara SH. Auxetic Stents as a Next Generation Solution for Vascular Diseases–A Review. Cardiovascular Engineering and Technology. 2026;17(5):654-673. doi:10.1007/s13239-026-00846-w

BibTeX
@article{Gupta2026,
  author = {Gupta, Khanish and Meena, Kusum and Chandrashekhara, S H},
  title = {Auxetic Stents as a Next Generation Solution for Vascular Diseases–A Review},
  journal = {Cardiovascular Engineering and Technology},
  year = {2026},
  volume = {17},
  number = {5},
  pages = {654--673},
  doi = {10.1007/s13239-026-00846-w}
}
Kostenlos starten →