Hemodynamic Shear Stress Patterns in Abdominal Aortic Aneurysms and Healthy Aortas: A CFD Study

Spyridon C Katsoudas, Panagiotis D Linardopoulos, Anastasios A Raptis, Konstantinos G Moulakakis, John D Kakisis, Konstantinos T Spanos, Miltiadis I Matsagkas, Athanasios D Giannoukas, Christos G Manopoulos, Efstratios E Tzirtzilakis, Michalis A Xenos iD

Cardiovascular Engineering and Technology · 2026

DOI: 10.1007/s13239-026-00823-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Cardiovascular Engineering and Technology, 2026. Verfasst von Spyridon C Katsoudas und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mathematics, University of Ioannina, Ioannina, 45110, Greece. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Aorta, Abdominal, Models, Cardiovascular, Hemodynamics. Die Arbeit nennt 29 Literaturangaben. Gefördert von: European Union-NextGeneration, European Union–NextGeneration.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Abdominal aortic aneurysms (AAAs) remain a major cause of mortality, with rupture risk still primarily assessed by maximum diameter. Specialized hemodynamic indices from Computational Fluid Dynamics (CFD) may provide predictive insight into AAA progression. METHODS: We performed a comparative CFD study of 10 healthy-control infrarenal aortas and 15 AAAs, utilizing the open source software SimVascular. Blood was modeled as a Newtonian fluid and pulsatile inlet conditions were applied, extracted from multiscale modeling. Three-element Windkessel (RCR) models were imposed at the iliac outlets to capture physiologic flow distribution. Time Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI) and Relative Residence Time (RRT) surface area coverage exposed to pathological regimes were quantified and compared between healthy and pathological models. Statistical analysis in two separate regions, the proximal neck/aneurysm sac and the iliacs, was conducted. RESULTS: Pathological-AAA models exhibited significantly bigger surface coverage of low TAWSS and high RRT compared to the healthy aortas in both studied areas. Although the coverage area of OSI was larger in AAAs, it didn't reach statistical significance at the infrarenal part, but only at the iliac region. CONCLUSION: The surface area exposed to lower shear and prolonged residence time provides strong evidence of AAA pathology in contrast with OSI, which offers limited information and cannot be a standalone index of pathology. These findings suggest that integrating TAWSS and RRT into clinical assessment may improve the prediction of aneurysm progression and rupture risk beyond diameter-based criteria.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, AbdominalAorta, AbdominalModels, CardiovascularHemodynamicsHumansStress, MechanicalBlood Flow VelocityRegional Blood FlowAgedCase-Control StudiesMaleComputer SimulationHydrodynamicsDisease ProgressionMiddle AgedFemalePulsatile FlowTime Factors

Stichwörter der Autor:innen

Abdominal aortic aneurysm (AAA)Computational fluid dynamics (CFD)Oscillatory shear index (OSI)RCR boundary conditionsRelative Residence Time (RRT)Time Averaged Wall shear stress (TAWSS)

Autor:innen und Institutionen

  • Department of Mathematics, University of Ioannina, Ioannina, 45110, Greece.
  • Laboratory of Biofluid Mechanics & Biomedical Technology, School of Mechanical Engineering, National Technical University of Athens, Athens, Zografou, 15772, Greece.
  • Department of Vascular Surgery, Attikon University Hospital, National and Kapodistrian University of Athens, Athens, 10679, Greece.
  • Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, 41334, Greece.
  • Department of Civil Engineering, University of the Peloponnese, Patras, 26334, Greece.
  • Department of Mathematics, University of Ioannina, Ioannina, 45110, Greece. mxenos@uoi.gr.

ORCID-Profile: Michalis A Xenos

Förderung

  • European Union-NextGeneration
  • European Union–NextGeneration

Zitieren

APA

Katsoudas, S. C., Linardopoulos, P. D., Raptis, A. A., Moulakakis, K. G., Kakisis, J. D., Spanos, K. T., Matsagkas, M. I., Giannoukas, A. D., Manopoulos, C. G., Tzirtzilakis, E. E., & Xenos, M. A. (2026). Hemodynamic Shear Stress Patterns in Abdominal Aortic Aneurysms and Healthy Aortas: A CFD Study. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-026-00823-3

Vancouver

Katsoudas SC, Linardopoulos PD, Raptis AA, Moulakakis KG, Kakisis JD, Spanos KT, et al. Hemodynamic Shear Stress Patterns in Abdominal Aortic Aneurysms and Healthy Aortas: A CFD Study. Cardiovascular Engineering and Technology. 2026. doi:10.1007/s13239-026-00823-3

BibTeX
@article{Katsoudas2026,
  author = {Katsoudas, Spyridon C and Linardopoulos, Panagiotis D and Raptis, Anastasios A and Moulakakis, Konstantinos G and Kakisis, John D and Spanos, Konstantinos T and Matsagkas, Miltiadis I and Giannoukas, Athanasios D and Manopoulos, Christos G and Tzirtzilakis, Efstratios E and Xenos, Michalis A},
  title = {Hemodynamic Shear Stress Patterns in Abdominal Aortic Aneurysms and Healthy Aortas: A CFD Study},
  journal = {Cardiovascular Engineering and Technology},
  year = {2026},
  doi = {10.1007/s13239-026-00823-3}
}
Kostenlos starten →