Kurz gefasst

Validierungsstudie in der Zeitschrift Cardiovascular Engineering and Technology, 2025. Verfasst von Bjørn-Jostein Singstad und 1 weiteren Autor:innen. Beteiligte Einrichtung: Medical Technology and E-health, Akershus University Hospital, Lørenskog, Norway. b.j.singstad@fys.uio.no. Hauptthemen laut MEDLINE: Electrocardiography, Signal Processing, Computer-Assisted, Neural Networks, Computer, Heart Rate. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nasjonalforeningen for Folkehelsen, Vestfold Hospital Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The electrocardiogram (ECG) is an almost universally accessible diagnostic tool for heart disease. An ECG is measured by using an electrocardiograph, and today’s electrocardiographs use built-in software to interpret the ECGs automatically after they are recorded. However, these algorithms exhibit limited performance, and therefore, clinicians usually have to manually interpret the ECG, regardless of whether an algorithm has interpreted it or not. Manual interpretation of the ECG can be time-consuming and requires specific skills. Therefore, better algorithms are clearly needed to make correct ECG interpretations more accessible and time-efficient. Algorithms based on artificial intelligence (AI) have demonstrated promising performance in various fields, including ECG interpretation, over the past few years and may represent an alternative to manual ECG interpretation by doctors.

Results

We trained and validated a convolutional neural network with an Inception architecture on a dataset with 88253 12-lead ECGs, and classified 30 of the most frequent annotated cardiac conditions in the dataset. We assessed two different loss functions and different ECG sampling rates and the best-performing model used double soft F1-loss and ECGs downsampled to 75Hz. This model achieved an F1-score of $$0.420\pm 0.017$$ 0.420 ± 0.017 , accuracy $$= 0.954 \pm 0.002$$ = 0.954 ± 0.002 , and an AUROC score of $$0.832 \pm 0.019$$ 0.832 ± 0.019 . An aggregated saliency map, showing the global importance of all 12 ECG leads for the 30 cardiac conditions, was generated using Local Interpretable Model-Agnostic Explanations (LIME). The global saliency map showed that the Inception model paid the most attention to the limb leads and the augmented leads and less importance to the precordial leads.

Conclusions

One of the more significant contributions that emerge from this study is the use of aggregated saliency maps to obtain global ECG lead importance for different cardiac conditions. In addition, we emphasized the relevance of evaluating different loss functions, and in this specific case, we found double soft F1-loss to be slightly better than binary cross-entropy (BCE). Finally, we found it somewhat surprising that drastic downsampling of the ECG led to higher performance than higher sampling frequencies, such as 500Hz. These findings contribute in several ways to our understanding of the artificial intelligence-based interpretation of ECGs, but further studies should be carried out to validate these findings in other datasets from other patient cohorts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographySignal Processing, Computer-AssistedNeural Networks, ComputerHeart RateHeart DiseasesAction PotentialsDiagnosis, Computer-AssistedDeep LearningHumansPredictive Value of TestsReproducibility of ResultsAlgorithmsDatabases, Factual

Stichwörter der Autor:innen

Convolutional neural networkDouble soft F1-lossECGExplainable AIMulti-label classification

Autor:innen und Institutionen

  • Medical Technology and E-health, Akershus University Hospital, Lørenskog, Norway. b.j.singstad@fys.uio.no.
  • Department of Endocrinology, Obesity and Nutrition, Vestfold Hospital Trust, Tønsberg, Norway. b.j.singstad@fys.uio.no.
  • Department of Research and Innovation, Vestfold Hospital Trust, Tønsberg, Norway. b.j.singstad@fys.uio.no.
  • Institute of Clinical Medicine, University of Oslo, Oslo, Norway. b.j.singstad@fys.uio.no.
  • Department of Biomedical Engineering, Institut Teknologi Bandung, Bandung, Indonesia.

ORCID-Profile: Bjørn-Jostein Singstad

Förderung

  • Nasjonalforeningen for Folkehelsen
  • Vestfold Hospital Trust

Zitieren

APA

Singstad, B. J., & Muten, E. M. (2025). Assessing the Impact of Downsampled ECGs and Alternative Loss Functions in Multi-Label Classification of 12-Lead ECGs. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-025-00797-8

Vancouver

Singstad BJ, Muten EM. Assessing the Impact of Downsampled ECGs and Alternative Loss Functions in Multi-Label Classification of 12-Lead ECGs. Cardiovascular Engineering and Technology. 2025. doi:10.1007/s13239-025-00797-8

BibTeX
@article{Singstad2025,
  author = {Singstad, Bjørn-Jostein and Muten, Eraraya Morenzo},
  title = {Assessing the Impact of Downsampled ECGs and Alternative Loss Functions in Multi-Label Classification of 12-Lead ECGs},
  journal = {Cardiovascular Engineering and Technology},
  year = {2025},
  doi = {10.1007/s13239-025-00797-8}
}
Kostenlos starten →