Design and Prototyping of a Novel Triple Lumen Photo-Angioplasty Device: Lumi-Solve-T
Cardiovascular Engineering and Technology · 2025
DOI: 10.1007/s13239-024-00768-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, 2025. Verfasst von Aldous Tria und 11 weiteren Autor:innen. Beteiligte Einrichtung: Monash Institute of Medical Engineering, Monash University, Melbourne, Australia. Hauptthemen laut MEDLINE: Muscle, Smooth, Vascular, Myocytes, Smooth Muscle, Computer-Aided Design, Angioplasty, Balloon. Die Arbeit nennt 9 Literaturangaben. Gefördert von: National Health and Medical Research Council.
Abstract (Originalsprache)
PURPOSE: A triple lumen iteration of the novel photo-angioplasty drug eluting balloon catheter (DEBc) Lumi-Solve may be compromised by guidewire shadow (GWS)-mediated attenuation of balloon surface drug activation. The current study aimed to design and evaluate a novel triple lumen prototype, designated Lumi-Solve-T, to circumvent these issues. METHODS: Effects of guidewire shadowing (GWS) on vascular smooth muscle cell (VSMC) proliferation was evaluated using the MTT assay. In-silico modelling of GWS in the novel triple lumen design was conducted. Computer-aided design (CAD) and finite element analysis (FEA) contributed to development of a novel triple lumen catheter. 3D printing of rudimentary and refined prototypes of the catheter together with assembly of a novel fibre-optic (FO) complex and ex-vivo evaluation of the triple lumen device, Lumi-Solve T, was also performed. RESULTS: GW insertion in a parallel triple lumen FO: GW port orientation demonstrated significantly reduced inhibition of VSMC proliferation after 7 days confirming the need for an alternative triple lumen design. In-silico analysis identified a multi-fibre FO sleeve design supported uniform, radial and uninterrupted UV365nm light transmission to the angioplasty balloon surface. FEA confirmed a multi-fibre FO ribbon design afforded a practical method of FO sleeve generation and facilitated a novel hub configuration able to afford a FO ribbon to sleeve transition. 3D printed prototypes demonstrated the utility of the novel design. CONCLUSIONS: A dedicated third port and lumen for the Lumi-Solve FO is required for optimal balloon surface photo-activation. A novel triple lumen design, Lumi-Solve-T, incorporating a ribbon to sleeve FO transition and novel hub design offers a realistic solution to current device limitations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Monash Institute of Medical Engineering, Monash University, Melbourne, Australia.
- Eastern Health Clinical School, Monash University, Melbourne, Australia.
- Department of Anatomy and Developmental Biology, Monash University, Melbourne, Australia.
- Department of Radiology, Eastern Health, Box Hill Hospital, Melbourne, Australia.
- Eastern Health Clinical School, Monash University, Melbourne, Australia. Anthony.dear@monash.edu.
- Department of Vascular Surgery, Eastern Health, Box Hill Hospital, Melbourne, Australia. Anthony.dear@monash.edu.
ORCID-Profile: Anthony E Dear
Förderung
- National Health and Medical Research Council
Zitieren
APA
Tria, A., Dharma, A., Spiegel, L., Rodda, A. E., Allada, A., Sluka, P., Menon, A. S., Prabaharan, E., Wettesinghe, P. V., Adams, J. W., Spanger, M., & Dear, A. E. (2025). Design and Prototyping of a Novel Triple Lumen Photo-Angioplasty Device: Lumi-Solve-T. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-024-00768-5
Vancouver
Tria A, Dharma A, Spiegel L, Rodda AE, Allada A, Sluka P, et al. Design and Prototyping of a Novel Triple Lumen Photo-Angioplasty Device: Lumi-Solve-T. Cardiovascular Engineering and Technology. 2025. doi:10.1007/s13239-024-00768-5
BibTeX
@article{Tria2025,
author = {Tria, Aldous and Dharma, Anak and Spiegel, Loren and Rodda, Andrew E and Allada, Asvini and Sluka, Pavel and Menon, Amarnath Sangeetha and Prabaharan, Ethan and Wettesinghe, Pulasthi V and Adams, Justin W and Spanger, Manfred and Dear, Anthony E},
title = {Design and Prototyping of a Novel Triple Lumen Photo-Angioplasty Device: Lumi-Solve-T},
journal = {Cardiovascular Engineering and Technology},
year = {2025},
doi = {10.1007/s13239-024-00768-5}
}