EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development

Sita Drost iD, Cornelis J Drost

Cardiovascular Engineering and Technology · 2025

DOI: 10.1007/s13239-024-00765-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, 2025. Verfasst von Sita Drost und 1 weiteren Autor:innen. Beteiligte Einrichtung: Transonic Europe B.V., Business Park Stein 205, Elsloo, 6181 MB, The Netherlands. sita.drost@transonic.com. Hauptthemen laut MEDLINE: Coronary Artery Bypass, Vascular Patency, Models, Cardiovascular, Computer Simulation. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.

Methods

Uncertainty quantification was performed on a realistic multiscale numerical model of the coronary circulation, guided by Morris screening sensitivity analysis of a simpler, lumped-parameter model. Simulation results were qualitatively verified against results of a recent clinical study.

Results

Correspondence with clinical study data is reasonable, especially considering that the model was not fitted in any way. Stenosis severity was confirmed to be an influential parameter. However, also cardiac period and graft diameter were observed to be important, particularly for mean flow rate and pulsatility index.

Conclusion

Metrics quantifying the flow waveform’s diastolic dominance show the highest sensitivity to graft stenosis, and seem to be least affected by autoregulation. Among these, the novel diastolic resistance index shows the strongest sensitivity to stenosis severity. Significance The approach used in this study is expected to benefit the development of improved patency metrics, by allowing medical engineers to include sensitivity and uncertainty in assessing, in-silico, the potential of novel metrics, thus enabling them to provide better guidance in the design of clinical studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery BypassVascular PatencyModels, CardiovascularComputer SimulationCoronary CirculationCoronary VesselsGraft Occlusion, VascularCoronary StenosisHumansUncertaintyBlood Flow VelocityTime FactorsPredictive Value of TestsTreatment Outcome

Stichwörter der Autor:innen

CABGComputational fluid dynamicsHemodynamicsSensitivity analysisTTFMUncertainty quantification

Autor:innen und Institutionen

  • Transonic Europe B.V., Business Park Stein 205, Elsloo, 6181 MB, The Netherlands. sita.drost@transonic.com.
  • Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.

ORCID-Profile: Sita Drost

Zitieren

APA

Drost, S., & Drost, C. J. (2025). Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-024-00765-8

Vancouver

Drost S, Drost CJ. Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development. Cardiovascular Engineering and Technology. 2025. doi:10.1007/s13239-024-00765-8

BibTeX
@article{Drost2025,
  author = {Drost, Sita and Drost, Cornelis J},
  title = {Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development},
  journal = {Cardiovascular Engineering and Technology},
  year = {2025},
  doi = {10.1007/s13239-024-00765-8}
}
Kostenlos starten →