EUVIMEDEUVIMED entdecken
Crossref

Activation of a Soft Robotic Left Ventricular Phantom Embedded in a Closed-Loop Cardiovascular Simulator: A Computational and Experimental Analysis

Nele Demeersseman iD, Maria Rocchi iD, Heleen Fehervary iD, Guillermo Fernández Collazo iD, Bart Meyns iD, Libera Fresiello iD, Nele Famaey iD

Cardiovascular Engineering and Technology · 2025

DOI: 10.1007/s13239-024-00755-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, 2025. Verfasst von Nele Demeersseman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Biomechanics Section, KU Leuven, Leuven, Belgium. nele.demeersseman@kuleuven.be. Hauptthemen laut MEDLINE: Models, Cardiovascular, Phantoms, Imaging, Computer Simulation, Ventricular Function, Left. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Fonds Wetenschappelijk Onderzoek, KU Leuven.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Cardiovascular simulators are used in the preclinical testing phase of medical devices. Their reliability increases the more they resemble clinically relevant scenarios. In this study, a physiologically actuated soft robotic left ventricle (SRLV) embedded in a hybrid (in silico- in vitro) simulator of the cardiovascular system is presented, along with its experimental and computational analysis. METHODS: A SRLV phantom, developed from a patient's CT scan using polyvinyl alcohol (PVA), is embedded in a hybrid cardiovascular simulator. We present an activation method in which the hydraulic pressure external ( P e ( t ) ) to the SRLV is continuously adapted to regulate the left ventricular volume ( V i ( t ) ), considering the geometry and material behavior of the SRLV and the left ventricular pressure ( P i ( t ) ). This activation method is verified using a finite element (FE) model of the SRLV and validated in the hybrid simulator. Different hemodynamic profiles are presented to test the flexibility of the method. RESULTS: Both the FE model and hybrid simulator could represent the desired in silico data ( P i ( t ) , V i ( t ) ) with the implemented activation method, with deviations below 8.09% in the FE model and mainly < 10% errors in the hybrid simulator. Only two measurements out of 32 exceeded the 10% threshold due to simulator setup limitations. CONCLUSION: The activation method effectively allows to represent various pressure-volume loops, as verified numerically, and validated experimentally in the hybrid simulator. This work presents a high-fidelity platform designed to simulate cardiovascular conditions, offering a robust foundation for future testing of cardiovascular medical devices under physiological conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, CardiovascularPhantoms, ImagingComputer SimulationVentricular Function, LeftHeart VentriclesRoboticsHumansFinite Element AnalysisEquipment DesignReproducibility of Results

Stichwörter der Autor:innen

Finite element modelingHemodynamicsHybrid cardiovascular simulatorSoft roboticsTensile testing

Autor:innen und Institutionen

  • Biomechanics Section, KU Leuven, Leuven, Belgium. nele.demeersseman@kuleuven.be.
  • Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
  • Biomechanics Section, KU Leuven, Leuven, Belgium.
  • FIBEr KU Leuven Core Facility for Biomechanical Experimentation, KU Leuven, Leuven, Belgium.
  • Institute Biomedical Technology, Ghent University, Ghent, Belgium.
  • Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium.

ORCID-Profile: Nele Demeersseman, Maria Rocchi, Heleen Fehervary, Guillermo Fernández Collazo, Bart Meyns, Libera Fresiello, Nele Famaey

Förderung

  • Fonds Wetenschappelijk Onderzoek
  • KU Leuven

Zitieren

APA

Demeersseman, N., Rocchi, M., Fehervary, H., Collazo, G. F., Meyns, B., Fresiello, L., & Famaey, N. (2025). Activation of a Soft Robotic Left Ventricular Phantom Embedded in a Closed-Loop Cardiovascular Simulator: A Computational and Experimental Analysis. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-024-00755-w

Vancouver

Demeersseman N, Rocchi M, Fehervary H, Collazo GF, Meyns B, Fresiello L, et al. Activation of a Soft Robotic Left Ventricular Phantom Embedded in a Closed-Loop Cardiovascular Simulator: A Computational and Experimental Analysis. Cardiovascular Engineering and Technology. 2025. doi:10.1007/s13239-024-00755-w

BibTeX
@article{Demeersseman2025,
  author = {Demeersseman, Nele and Rocchi, Maria and Fehervary, Heleen and Collazo, Guillermo Fernández and Meyns, Bart and Fresiello, Libera and Famaey, Nele},
  title = {Activation of a Soft Robotic Left Ventricular Phantom Embedded in a Closed-Loop Cardiovascular Simulator: A Computational and Experimental Analysis},
  journal = {Cardiovascular Engineering and Technology},
  year = {2025},
  doi = {10.1007/s13239-024-00755-w}
}
Kostenlos starten →