Shape-Setting of Self-Expanding Nickel–Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge
Cardiovascular Engineering and Technology · 2024
DOI: 10.1007/s13239-024-00717-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cardiovascular Engineering and Technology, 2024. Verfasst von Martina Bernini und 8 weiteren Autor:innen. Beteiligte Einrichtung: Biomechanics Research Centre (BioMEC), School of Engineering and Informatics, University of Galway, Galway, Ireland. Hauptthemen laut MEDLINE: Titanium, Prosthesis Design, Nickel, Materials Testing. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HORIZON EUROPE Marie Sklodowska-Curie Actions, National University Ireland, Galway.
Abstract (Originalsprache)
Purpose
Altered hemodynamics caused by the presence of an endovascular device may undermine the success of peripheral stenting procedures. Flow-enhanced stent designs are under investigation to recover physiological blood flow patterns in the treated artery and reduce long-term complications. However, flow-enhanced designs require the development of customised manufacturing processes that consider the complex behaviour of Nickel-Titanium (Ni-Ti). While the manufacturing routes of traditional self-expanding Ni–Ti stents are well-established, the process to introduce alternative stent designs is rarely reported in the literature, with much of this information (especially related to shape-setting step) being commercially sensitive and not reaching the public domain, as yet.
Methods
A reliable manufacturing method was developed and improved to induce a helical ridge onto laser-cut and wire-braided Nickel–Titanium self-expanding stents. The process consisted of fastening the stent into a custom-built fixture that provided the helical shape, which was followed by a shape-setting in air furnace and rapid quenching in cold water. The parameters employed for the shape-setting in air furnace were thoroughly explored, and their effects assessed in terms of the mechanical performance of the device, material transformation temperatures and surface finishing.
Results
Both stents were successfully imparted with a helical ridge and the optimal heat treatment parameters combination was found. The settings of 500 °C/30 min provided mechanical properties comparable with the original design, and transformation temperatures suitable for stenting applications ( A f = 23.5 °C). Microscopy analysis confirmed that the manufacturing process did not alter the surface finishing. Deliverability testing showed the helical device could be loaded onto a catheter delivery system and deployed with full recovery of the expanded helical configuration.
Conclusion
This demonstrates the feasibility of an additional heat treatment regime to allow for helical shape-setting of laser-cut and wire-braided devices that may be applied to further designs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biomechanics Research Centre (BioMEC), School of Engineering and Informatics, University of Galway, Galway, Ireland.
- Vascular Flow Technologies, Dundee, UK.
- Division of Imaging and Science Technology, School of Medicine, Dundee, UK.
- National Heart and Lung Institute, Imperial College London, London, UK.
- Institut für Textiltechnik of RWTH, Aachen University, Aachen, Germany.
- Biomechanics Research Centre (BioMEC), School of Engineering and Informatics, University of Galway, Galway, Ireland. ted.vaughan@universityofgalway.ie.
ORCID-Profile: Martina Bernini
Förderung
- HORIZON EUROPE Marie Sklodowska-Curie Actions
- National University Ireland, Galway
Zitieren
APA
Bernini, M., Hellmuth, R., O'Sullivan, M., Dunlop, C., McKenna, C. G., Lucchetti, A., Gries, T., Ronan, W., & Vaughan, T. J. (2024). Shape-Setting of Self-Expanding Nickel–Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge. Cardiovascular Engineering and Technology. https://doi.org/10.1007/s13239-024-00717-2
Vancouver
Bernini M, Hellmuth R, O'Sullivan M, Dunlop C, McKenna CG, Lucchetti A, et al. Shape-Setting of Self-Expanding Nickel–Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge. Cardiovascular Engineering and Technology. 2024. doi:10.1007/s13239-024-00717-2
BibTeX
@article{Bernini2024,
author = {Bernini, Martina and Hellmuth, Rudolf and O'Sullivan, Mike and Dunlop, Craig and McKenna, Ciara G and Lucchetti, Agnese and Gries, Thomas and Ronan, William and Vaughan, Ted J},
title = {Shape-Setting of Self-Expanding Nickel–Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge},
journal = {Cardiovascular Engineering and Technology},
year = {2024},
doi = {10.1007/s13239-024-00717-2}
}
EUVIMED