Removal of Staphylococcus aureus using electro-fenton, UV/H2O2, and combination of electro-fenton and UV/H2O2 processes; optimization of operational parameters
Applied Water Science · 2024-05 · 14 (5)
DOI: 10.1007/s13201-024-02151-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Water Science, online erschienen am 13.04.2024. Verfasst von Asiyeh Dokhani und 5 weiteren Autor:innen. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Staphylococcus aureus ( S. aureus ) is an opportunistic pathogen of the gram-positive variety, known to cause a range of severe infections including cellulitis, pneumonia, osteomyelitis, endocarditis, and sepsis. These infections are associated with significant morbidity and mortality rates in both hospital and community settings. Therefore, it is important to remove S. aureus from the aqueous solution. The present study employed response surface methodology as an effective strategy to optimize the removal of S. aureus through the electro-Fenton (EF), UV/H 2 O 2 , and combination EF-UV/H 2 O 2 processes. Under the optimized conditions, the maximum removal efficiency in the EF process of 48.5%, UV/H 2 O 2 process of 36.2%, and combination EF-UV/H 2 O 2 process of 100%. The optimum condition for removal efficiency using combination EF-UV/H 2 O 2 process of 100% was attained at S. aureus concentration of 5 × 10 6 CFU mL −1 , current density of 8.0 mA cm −2 , H 2 O 2 dosage of 170 µL L −1 , and 2 lamps UV during 7.0 min. Both the production of • OH in the EF and UV/H 2 O 2 process and the additive oxidation effect of UV/H 2 O 2 are the main reasons for the better performance of combination EF-UV/H 2 O 2 process. The results indicate that the EF-UV/H 2 O 2 process is highly promising and environmentally sustainable method for treating wastewater samples contaminated with S. aureus.
Zitieren
APA
Dokhani, A., kheirkhah, B., Kalantar-Neyestanaki, D., Rokhbakhsh-Zamin, F., Dolatabadi, M., & Ahmadzadeh, S. (2024). Removal of Staphylococcus aureus using electro-fenton, UV/H2O2, and combination of electro-fenton and UV/H2O2 processes; optimization of operational parameters. Applied Water Science, 14(5). https://doi.org/10.1007/s13201-024-02151-0
Vancouver
Dokhani A, kheirkhah B, Kalantar-Neyestanaki D, Rokhbakhsh-Zamin F, Dolatabadi M, Ahmadzadeh S. Removal of Staphylococcus aureus using electro-fenton, UV/H2O2, and combination of electro-fenton and UV/H2O2 processes; optimization of operational parameters. Applied Water Science. 2024;14(5). doi:10.1007/s13201-024-02151-0
BibTeX
@article{Dokhani2024,
author = {Dokhani, Asiyeh and kheirkhah, Babak and Kalantar-Neyestanaki, Davood and Rokhbakhsh-Zamin, Farokh and Dolatabadi, Maryam and Ahmadzadeh, Saeid},
title = {Removal of Staphylococcus aureus using electro-fenton, UV/H2O2, and combination of electro-fenton and UV/H2O2 processes; optimization of operational parameters},
journal = {Applied Water Science},
year = {2024},
volume = {14},
number = {5},
doi = {10.1007/s13201-024-02151-0}
}
EUVIMED