Investigating the Physiology of Cannabis Intoxication and Impairment Using Wearable Sensors
Journal of Medical Toxicology · 04.11.2026
DOI: 10.1007/s13181-026-01164-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Toxicology, online erschienen am 04.11.2026. Verfasst von Eric E Kaczor und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY…. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American College of Medical Toxicology.
Abstract (Originalsprache)
Introduction
Cannabis decriminalization/legalization has increased the availability and recreational use of cannabis products. Unlike ethanol, there are no standard validated assessments to identify cannabis-induced intoxication and impairment. The objective of this study was to show that wearable sensors can objectively identify cannabis intoxication.
Methods
This observational study evaluated participants who smoked their personal cannabis products. Heart rate (HR), skin temperature, electrodermal activity, and accelerometry data were continuously collected using a wrist-worn sensor (Empatica EmbracePlus). Participants were assessed using the DRUID© impairment application, the Subjective High Assessment Scale (SHAS) surveys, and 2-minute periods each of sit/stand/walk exercises. Participants performed the study protocol at home while monitored remotely by study staff. The biometric data, DRUID© scores, and subjective intoxication scores were analyzed using descriptive statistics, paired t-tests, Welch tests, and repeated measures analysis of variance (ANOVA). This data was used to train multiple machine learning (ML) models.
Results
Statistical analysis was performed on 17/20 enrolled participants who provided complete data sets. In this cohort, cannabis intoxication caused significant changes in HR and aggregate accelerometry. Non-significant decreases in limb electrodermal activity and increases in limb temperature were recorded. Significant changes in subjective intoxication (SHAS) and objective impairment (DRUID©) were observed. The best performing proof-of-concept ML models were better at detecting subjective intoxication (balanced accuracy of 0.864) than impairment (balanced accuracy of 0.763).
Conclusions
Wearable sensors can detect physiologic changes in participants intoxicated with cannabis. This biometric data can be used to create ML models to detect cannabis-induced impairment and subjective intoxication.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA. erickacz428@gmail.com.
- Department of Industrial and Systems Engineering, University at Buffalo, State University of New York, Buffalo, NY, USA.
- Department of Psychology, Colorado State University, Fort Collins, CO, USA.
- Department of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
Förderung
- American College of Medical Toxicology
Zitieren
APA
Kaczor, E. E., Golleru, M., Smith, E. E., Conner, B. T., Vaid, R. A., Mitchell, M., Cavuoto, L., & Kelleran, K. J. (2026). Investigating the Physiology of Cannabis Intoxication and Impairment Using Wearable Sensors. Journal of Medical Toxicology. https://doi.org/10.1007/s13181-026-01164-2
Vancouver
Kaczor EE, Golleru M, Smith EE, Conner BT, Vaid RA, Mitchell M, et al. Investigating the Physiology of Cannabis Intoxication and Impairment Using Wearable Sensors. Journal of Medical Toxicology. 2026. doi:10.1007/s13181-026-01164-2
BibTeX
@article{Kaczor2026,
author = {Kaczor, Eric E and Golleru, Manohar and Smith, Emma E and Conner, Bradley T and Vaid, Raizada A and Mitchell, Morgan and Cavuoto, Lora and Kelleran, Kyle J},
title = {Investigating the Physiology of Cannabis Intoxication and Impairment Using Wearable Sensors},
journal = {Journal of Medical Toxicology},
year = {2026},
doi = {10.1007/s13181-026-01164-2}
}
EUVIMED