EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report

Leann N Tulisiak, Mackenzie E Loesing, Alexander Ljungberg, Eric E Kaczor

Journal of Medical Toxicology · 2025

DOI: 10.1007/s13181-025-01090-9 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Medical Toxicology, 2025. Verfasst von Leann N Tulisiak und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY…. Hauptthemen laut MEDLINE: Methemoglobinemia, Phenazopyridine, Oximetry, Hypoxia. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Significant cases of methemoglobinemia will cause a signal interference in traditional dual-wavelength pulse oximetry leading to the classic finding of “refractory hypoxemia”. As smartwatches begin to incorporate pulse oximetry capabilities, it is unclear whether these devices will demonstrate the same type of interference in the presence of methemoglobinemia. This article reports a case where a patient’s Apple Watch© reported a hypoxemia alert in the setting of phenazopyridine induce methemoglobinemia. CASE REPORT: This is a case report of a 71-year-old female whose Apple Watch© reported a hypoxemia alarm in the setting of methemoglobinemia caused by phenazopyridine use. The patient’s smartwatch began signaling hypoxemia alerts the day before she noticed clinical cyanosis. 24 hours after the hypoxemia alerts began, she presented to the Emergency Department (ED) with shortness of breath and blue discoloration of skin. The Apple Watch© recorded oxygen saturation readings between 73% and 86%. Upon arrival to the ED, the patient’s SpO2 was 84% on traditional hospital-grade dual-wavelength pulse oximetry and her methemoglobin level was 19.8%. Her symptoms and methemoglobinemia resolved after administration of 1 mg/kg of IV methylene blue. CONCLUSION: Pulse oximetry used in smartwatch technology can trigger a hypoxemia alarm in the presence of drug-induced methemoglobinemia. If demonstrated to be a reproducible finding, smartwatch technology has the potential to be used as part of an early detection system for clinically significant methemoglobinemia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MethemoglobinemiaPhenazopyridineOximetryHypoxiaClinical AlarmsHumansFemaleAgedPredictive Value of TestsOxygen Saturation

Stichwörter der Autor:innen

BiosensorsMethemoglobinemiaPhenazopyridinePulse OximetryWearable Electronic Devices

Substanzen

Phenazopyridine

Autor:innen und Institutionen

  • Department of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
  • Department of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA. erickacz428@gmail.com.

Zitieren

APA

Tulisiak, L. N., Loesing, M. E., Ljungberg, A., & Kaczor, E. E. (2025). Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report. Journal of Medical Toxicology. https://doi.org/10.1007/s13181-025-01090-9

Vancouver

Tulisiak LN, Loesing ME, Ljungberg A, Kaczor EE. Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report. Journal of Medical Toxicology. 2025. doi:10.1007/s13181-025-01090-9

BibTeX
@article{Tulisiak2025,
  author = {Tulisiak, Leann N and Loesing, Mackenzie E and Ljungberg, Alexander and Kaczor, Eric E},
  title = {Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report},
  journal = {Journal of Medical Toxicology},
  year = {2025},
  doi = {10.1007/s13181-025-01090-9}
}
Kostenlos starten →