EUVIMEDEUVIMED entdecken
Metaanalyse

Cerebral embolic protection in transcatheter aortic valve implantation (TAVI): a pooled analysis of 4091 patients

Mahmoud Balata, Mohamed Ibrahim Gbreel, Mohamed Hamouda Elkasaby, Ahmed Samy Badran, Marwa Hassan, Ralf Westenfeld, Roman Pfister, Sebastian Zimmer, Marc Ulrich Becher, Georg Nickenig, Atsushi Sugiura

Cardiovascular Intervention and Therapeutics · 2025

DOI: 10.1007/s12928-025-01128-3 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Cardiovascular Intervention and Therapeutics, 2025. Verfasst von Mahmoud Balata und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine and Cardiology, Friedrich-Alexander University of Erlangen-Nuremberg, Erlangen, Germany. dr.mahmoud.balata@gmail.com. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Embolic Protection Devices, Intracranial Embolism, Stroke. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly used for severe aortic stenosis, but debris embolization during the procedure can lead to strokes, impacting survival and quality of life. The role of cerebral embolic protection devices (CEPDs) in mitigating stroke risk remains debated. We aim to evaluate the impact of CEPDs on the risk of stroke and neurocognitive outcomes after TAVI. METHODS: Six databases (PubMed, Scopus, Web of Science, Cochrane, Embase, and Ovid) were searched until 20 January 2023. Original randomized controlled trials (RCTs) were only included and critically appraised using the Cochrane risk of bias (ROB) tool. RESULTS: Seven RCTs (4091 patients) were analyzed. CEPDs significantly reduced the risk of disabling stroke within 2-5 days post-TAVI (relative risk = 0.455, 95% CI: [0.214, 0.967]; p = 0.041). However, there was no significant difference in disabling stroke risk between the two groups at the 30-day follow-up (relative risk = 1.295, 95% CI: [0.373, 4.493]; p = 0.684). No significant differences were observed in non-disabling or overall stroke rates at 2-5 days, 30 days, or 90 days. Additionally, CEPDs did not significantly affect risks of life-threatening bleeding, major vascular complications, mortality, or acute kidney injury. CONCLUSION: CEPDs are effective in reducing disabling stroke risk in the immediate post-TAVI period (2-5 days) but did not significantly affect the rates of non-disabling stroke, overall stroke, or disabling stroke after 30 days when compared to non-CEPD use. These findings suggest that CEPDs may offer short-term neuroprotection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisEmbolic Protection DevicesIntracranial EmbolismStrokeTranscatheter Aortic Valve ReplacementHumansRandomized Controlled Trials as Topic

Stichwörter der Autor:innen

Cerebral embolic protectionMeta-analysisNeurological complicationsSystematic reviewTranscatheter valve implantation

Autor:innen und Institutionen

  • Department of Internal Medicine and Cardiology, Friedrich-Alexander University of Erlangen-Nuremberg, Erlangen, Germany. dr.mahmoud.balata@gmail.com.
  • Faculty of Medicine, October 6 University, Giza, Egypt.
  • Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
  • Faculty of Medicine, Ain Shams University, Cairo, Egypt.
  • Department of Immunology, Theodor Bilharz Research Institute, Giza, Egypt.
  • Department of Internal Medicine and Cardiology, University Hospital Duesseldorf, Düsseldorf, Germany.

Zitieren

APA

Balata, M., Gbreel, M. I., Elkasaby, M. H., Badran, A. S., Hassan, M., Westenfeld, R., Pfister, R., Zimmer, S., Becher, M. U., Nickenig, G., & Sugiura, A. (2025). Cerebral embolic protection in transcatheter aortic valve implantation (TAVI): a pooled analysis of 4091 patients. Cardiovascular Intervention and Therapeutics. https://doi.org/10.1007/s12928-025-01128-3

Vancouver

Balata M, Gbreel MI, Elkasaby MH, Badran AS, Hassan M, Westenfeld R, et al. Cerebral embolic protection in transcatheter aortic valve implantation (TAVI): a pooled analysis of 4091 patients. Cardiovascular Intervention and Therapeutics. 2025. doi:10.1007/s12928-025-01128-3

BibTeX
@article{Balata2025,
  author = {Balata, Mahmoud and Gbreel, Mohamed Ibrahim and Elkasaby, Mohamed Hamouda and Badran, Ahmed Samy and Hassan, Marwa and Westenfeld, Ralf and Pfister, Roman and Zimmer, Sebastian and Becher, Marc Ulrich and Nickenig, Georg and Sugiura, Atsushi},
  title = {Cerebral embolic protection in transcatheter aortic valve implantation (TAVI): a pooled analysis of 4091 patients},
  journal = {Cardiovascular Intervention and Therapeutics},
  year = {2025},
  doi = {10.1007/s12928-025-01128-3}
}
Kostenlos starten →