EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of pullback speed on evaluation of lipid core plaque using near-infrared spectroscopy-intravascular ultrasound

Tetsuharu Kasahara, Hideki Kitahara, Kenta Takou, Kazuya Tateishi, Yuichi Saito, Ken Kato, Takashi Iimori, Yoshio Kobayashi

Cardiovascular Intervention and Therapeutics · 2025

DOI: 10.1007/s12928-025-01124-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiovascular Intervention and Therapeutics, 2025. Verfasst von Tetsuharu Kasahara und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Chiba University Hospital, Chiba, Japan. Hauptthemen laut MEDLINE: Ultrasonography, Interventional, Plaque, Atherosclerotic, Coronary Artery Disease, Coronary Vessels. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) can assess the amount of lipid core plaque, and the latest generation catheter allows for imaging at several different pullback speeds. The purpose of this study was to investigate the impact of pullback speed on evaluation of lipid core plaque using the latest generation NIRS-IVUS catheter. Patients with coronary artery disease who underwent coronary angiography or percutaneous coronary intervention with NIRS-IVUS examination at 2 different pullback speeds (0.5 and 2.0 mm/sec) for the same vessel were enrolled. The values of lipid core burden index (LCBI) and maxLCBI4mm were compared between the images recorded with pullback speeds of 0.5 and 2.0 mm/sec, and match or mismatch of the location where maxLCBI4mm was detected was investigated. In a total of 286 NIRS-IVUS image sets, the location of maxLCBI4mm measured at 0.5 and 2.0 mm/sec was mismatched in 81 (28.3%) image sets. In comparison by vessel type, 20.8% were mismatched in LAD, 31.1% in LCx, and 37.8% in RCA ( p = 0.023). In 205 image sets with matched maxLCBI4mm location, the maxLCBI4mm value at 2.0 mm/sec was significantly greater compared with that at 0.5 mm/sec (348.0 vs. 302.0 in median, p < 0.001). In a substantial proportion of patients, the location of maxLCBI4mm values measured at 0.5 and 2.0 mm/sec was mismatched. In the image sets with matched maxLCBI4mm location, the maxLCBI4mm value at 2.0 mm/sec was significantly greater compared with that at 0.5 mm/sec. These results should be noted when applying the cut-off values of maxLCBI4mm recorded at 2.0 mm/sec. Graphical abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, InterventionalPlaque, AtheroscleroticCoronary Artery DiseaseCoronary VesselsLipidsHumansSpectroscopy, Near-InfraredMaleFemaleMiddle AgedAgedCoronary AngiographyPercutaneous Coronary Intervention

Stichwörter der Autor:innen

Intravascular ultrasoundLipid core burden indexNear-infrared spectroscopyPull-back speed

Substanzen

Lipids

Autor:innen und Institutionen

  • Department of Radiology, Chiba University Hospital, Chiba, Japan.
  • Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba, Chiba, 260-8677, Japan. hidekitahara0306@gmail.com.
  • Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba, Chiba, 260-8677, Japan.

Zitieren

APA

Kasahara, T., Kitahara, H., Takou, K., Tateishi, K., Saito, Y., Kato, K., Iimori, T., & Kobayashi, Y. (2025). Impact of pullback speed on evaluation of lipid core plaque using near-infrared spectroscopy-intravascular ultrasound. Cardiovascular Intervention and Therapeutics. https://doi.org/10.1007/s12928-025-01124-7

Vancouver

Kasahara T, Kitahara H, Takou K, Tateishi K, Saito Y, Kato K, et al. Impact of pullback speed on evaluation of lipid core plaque using near-infrared spectroscopy-intravascular ultrasound. Cardiovascular Intervention and Therapeutics. 2025. doi:10.1007/s12928-025-01124-7

BibTeX
@article{Kasahara2025,
  author = {Kasahara, Tetsuharu and Kitahara, Hideki and Takou, Kenta and Tateishi, Kazuya and Saito, Yuichi and Kato, Ken and Iimori, Takashi and Kobayashi, Yoshio},
  title = {Impact of pullback speed on evaluation of lipid core plaque using near-infrared spectroscopy-intravascular ultrasound},
  journal = {Cardiovascular Intervention and Therapeutics},
  year = {2025},
  doi = {10.1007/s12928-025-01124-7}
}
Kostenlos starten →