EUVIMEDEUVIMED entdecken
Open Access

Strain Gauge Analysis of Three Different Sagittal Split Ramus Osteotomy Modifications

Frederico Felipe Antonio de Oliveira Nascimento iD, John Paul Stella, Leandro Eduardo Klüppel iD, Leonardo Flores Luthi, Carla Tatiana Mota Anflor iD

Journal of Maxillofacial and Oral Surgery · 2026-08 · 25 (4) · 1035-1041

DOI: 10.1007/s12663-026-03057-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Maxillofacial and Oral Surgery, online erschienen am 07.05.2026. Verfasst von Frederico Felipe Antonio de Oliveira Nascimento und 4 weiteren Autor:innen. Beteiligte Einrichtung: Unidade de Cirurgia e Traumatologia Bucomaxilofacial, Hospital de Base de Brasília, Setor Médico e Hospitalar sul 101, Área especial sem número, Bras…. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study aims to analyze the deformation of screws under vertical load across three different sagittal split osteotomy designs proposed by Epker, Wolford, and Wyatt. Materials and Methods Thirty polyurethane hemimandibles were separated into three groups ( n = 10) according to osteotomy design. All specimens received standardized fixation with three positional titanium screws in an inverted L configuration. Strain gauges were bonded to each screw head to record deformation during vertical loading (1 mm/min) until failure. Peak load and deformation were measured. Data were analyzed using the Kruskal–Wallis test (α = 0.05).

Results

The Wolford design (Group II) had the highest mean load and most even stress distribution, indicating better stability. The Epker design (Group I) showed stress at screw 1, while the Wyatt design (Group III) had lower load resistance, more variability, early failure, and stress at screw 3. Screw 2 was most stable across all groups with the lowest deformation.

Conclusion

SSRO design affects force distribution. Techniques maintaining proximal segment thickness (Groups I and II) improve load dissipation. Group III modification shows less stability with inverted-L fixation. Strain-gauge analysis reveals stress patterns, with screw 2 as a key mechanical zone. Surgical planning should consider osteotomy design and anatomy to enhance fixation stability and minimize failure risk.

Schlagwörter

Stichwörter der Autor:innen

ExtensometerSagittal split osteotomyStressVertical forces

Autor:innen und Institutionen

  • Unidade de Cirurgia e Traumatologia Bucomaxilofacial, Hospital de Base de Brasília, Setor Médico e Hospitalar sul 101, Área especial sem número, Brasília, 70330-150 DF Brazil.
  • Oral and Maxillofacial Surgery Department at John Peter Smith Hospital, Fort Worth, TX USA.
  • School of Dentistry at Parana Federal University, Paraná, Brazil.
  • Private practice, Florianópolis, Brazil.
  • Brasilia University, Brasília, Brazil.

ORCID-Profile: Frederico Felipe Antonio de Oliveira Nascimento, Leandro Eduardo Klüppel, Carla Tatiana Mota Anflor

Zitieren

APA

de Oliveira Nascimento, F. F. A., Stella, J. P., Klüppel, L. E., Luthi, L. F., & Anflor, C. T. M. (2026). Strain Gauge Analysis of Three Different Sagittal Split Ramus Osteotomy Modifications. Journal of Maxillofacial and Oral Surgery, 25(4), 1035-1041. https://doi.org/10.1007/s12663-026-03057-x

Vancouver

de Oliveira Nascimento FFA, Stella JP, Klüppel LE, Luthi LF, Anflor CTM. Strain Gauge Analysis of Three Different Sagittal Split Ramus Osteotomy Modifications. Journal of Maxillofacial and Oral Surgery. 2026;25(4):1035-1041. doi:10.1007/s12663-026-03057-x

BibTeX
@article{deOliveiraNascimento2026,
  author = {de Oliveira Nascimento, Frederico Felipe Antonio and Stella, John Paul and Klüppel, Leandro Eduardo and Luthi, Leonardo Flores and Anflor, Carla Tatiana Mota},
  title = {Strain Gauge Analysis of Three Different Sagittal Split Ramus Osteotomy Modifications},
  journal = {Journal of Maxillofacial and Oral Surgery},
  year = {2026},
  volume = {25},
  number = {4},
  pages = {1035--1041},
  doi = {10.1007/s12663-026-03057-x}
}
Kostenlos starten →