Accuracy of three-dimensional echocardiography in patients with prior anteroseptal myocardial infarction
Journal of Echocardiography · 2009
DOI: 10.1007/s12574-008-0002-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Echocardiography, 2009. Verfasst von Yoshiaki Maruyama und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Promotion, Saitama Medical Center, Saitama Medical University, 1981 Kamoda-Tsujidomachi, Kawagoe, 350-8550, Japan. ymaru@saitama…. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Echocardiography is the most feasible modality for monitoring cardiac volume and function. However, conventional two-dimensional echocardiography (2DE) is frequently not accurate in measuring cardiac performance in cases of abnormal left ventricular wall motion, because of the geometric assumptions. Quantitative gated scintigraphy and magnetic resonance imaging are reliable modalities, but are expensive and not feasible for repetitive use. Real-time three-dimensional echocardiography (RT3DE) has been proved to be applicable in daily practice. The purpose of this study was to confirm the superiority of RT3DE to 2DE in assessing cardiac volume and function in patients with abnormal wall motion. METHODS: The subjects were 41 patients with old anteroseptal myocardial infarction who underwent left ventricular volume and functional measurement by RT3DE, 2DE, and left ventriculography (LVG). End-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) from RT3DE and 2DE were measured and compared with results from LVG. RESULTS: RT3DE correlated well with LVG in measurements of EDV, ESV, and EF (r = 0.815, 0.940, and 0.812, respectively; P < 0.001 each). Likewise, 2DE correlated with LVG, but underestimated left ventricular volume, particularly EDV (r = 0.652, 0.909, and 0.761, respectively; P < 0.001 each). CONCLUSION: Values derived from RT3DE were closer to those from LVG than were values derived from 2DE. RT3DE provides important information on cardiac function in patients with prior anteroseptal myocardial infarction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health Promotion, Saitama Medical Center, Saitama Medical University, 1981 Kamoda-Tsujidomachi, Kawagoe, 350-8550, Japan. ymaru@saitama-med.ac.jp.
- Department of Cardiology, Saitama Medical Center, Saitama Medical University, 1981 Kamoda-Tsujidomachi, Kawagoe, 350-8550, Japan.
Zitieren
APA
Maruyama, Y., Toyama, K., Sato, S., Masaki, N., Kirimura, M., & Yoshimoto, N. (2009). Accuracy of three-dimensional echocardiography in patients with prior anteroseptal myocardial infarction. Journal of Echocardiography. https://doi.org/10.1007/s12574-008-0002-0
Vancouver
Maruyama Y, Toyama K, Sato S, Masaki N, Kirimura M, Yoshimoto N. Accuracy of three-dimensional echocardiography in patients with prior anteroseptal myocardial infarction. Journal of Echocardiography. 2009. doi:10.1007/s12574-008-0002-0
BibTeX
@article{Maruyama2009,
author = {Maruyama, Yoshiaki and Toyama, Kentaro and Sato, Shunichi and Masaki, Nobuyuki and Kirimura, Masato and Yoshimoto, Nobuo},
title = {Accuracy of three-dimensional echocardiography in patients with prior anteroseptal myocardial infarction},
journal = {Journal of Echocardiography},
year = {2009},
doi = {10.1007/s12574-008-0002-0}
}
EUVIMED