EUVIMEDEUVIMED entdecken
Evaluationsstudie

Ultraviolet (UV-C) Light Systems for the Inactivation of Feline Calicivirus and Tulane Virus in Model Fluid Foods

E Corson, B Pendyala, A Patras, D H D'Souza

Food and Environmental Virology · 2024

DOI: 10.1007/s12560-024-09614-2 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Food and Environmental Virology, 2024. Verfasst von E Corson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Food Science, University of Tennessee, 2600 River Drive, Knoxville, TN, 37996, USA. Hauptthemen laut MEDLINE: Ultraviolet Rays, Calicivirus, Feline, Virus Inactivation, Caliciviridae. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: USDA NIFA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional UV-C (254 nm) inactivation technologies have limitations and potential operator-safety risk. To overcome these disadvantages, novel UV-C light-emitting diodes (LED) are developed and investigated for their performance. This study aimed to determine the inactivation of human norovirus (HuNoV) surrogates, Tulane virus (TV), and feline calicivirus (FCV-F9), by UV-C (254 nm) in comparison to UV-C LED (279 nm) in phosphate-buffered saline (PBS) and coconut water (CW). Five-hundred microliters of FCV-F9 (~ 5 log plaque forming units (PFU)/mL) or TV (~ 6 log PFU/mL) were added to 4.5 mL PBS or CW in continuously stirred glass beakers and exposed to 254 nm UV-C for 0 up to 15 min (maximum dosage of 33.89 mJ/cm2) or 279 nm UV-C LED for 0 up to 2.5 min (maximum dosage of 7.03 mJ/cm2). Recovered viruses were assayed in duplicate from each treatment replicated thrice. Mixed model analysis of variance was used for data analysis. Significantly lower D10 values were obtained in PBS and CW (p ≤ 0.05) for both tested viruses using UV-C LED (279 nm) where FCV-F9 showed D10 values of 7.08 ± 1.75 mJ/cm2 and 3.75 ± 0.11 mJ/cm2, while using UV-C (254 nm) showed D10 values of 13.81 ± 0.40 mJ/cm2 and 6.43 ± 0.44 mJ/cm2 in PBS and CW, respectively. Similarly, lower D10 values were obtained for TV of 3.91 ± 1.03 mJ/cm2 and 4.26 ± 1.02 mJ/cm2 with 279 nm UV-C LED and were 18.76 ± 3.16 mJ/cm2 and 10.21 ± 1.48 mJ/cm2 with 254 nm UV-C in PBS and CW, respectively. Viral resistance to these treatments was fluid-matrix dependent. These findings indicate that use of 279 nm UV-C LED is more effective in inactivating HuNoV surrogates than conventional 254 nm UV-C in the tested fluids.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultraviolet RaysCalicivirus, FelineVirus InactivationCaliciviridaeAnimalsCatsFood IrradiationFood Microbiology

Stichwörter der Autor:innen

Feline calicivirusHuman norovirusLight-emitting diodesSurrogatesTulane virusUltraviolet light

Autor:innen und Institutionen

  • Department of Food Science, University of Tennessee, 2600 River Drive, Knoxville, TN, 37996, USA.
  • Tennessee State University, Nashville, TN, USA.
  • Department of Food Science, University of Tennessee, 2600 River Drive, Knoxville, TN, 37996, USA. ddsouza@utk.edu.

Förderung

  • USDA NIFA

Zitieren

APA

Corson, E., Pendyala, B., Patras, A., & D'Souza, D. H. (2024). Ultraviolet (UV-C) Light Systems for the Inactivation of Feline Calicivirus and Tulane Virus in Model Fluid Foods. Food and Environmental Virology. https://doi.org/10.1007/s12560-024-09614-2

Vancouver

Corson E, Pendyala B, Patras A, D'Souza DH. Ultraviolet (UV-C) Light Systems for the Inactivation of Feline Calicivirus and Tulane Virus in Model Fluid Foods. Food and Environmental Virology. 2024. doi:10.1007/s12560-024-09614-2

BibTeX
@article{Corson2024,
  author = {Corson, E and Pendyala, B and Patras, A and D'Souza, D H},
  title = {Ultraviolet (UV-C) Light Systems for the Inactivation of Feline Calicivirus and Tulane Virus in Model Fluid Foods},
  journal = {Food and Environmental Virology},
  year = {2024},
  doi = {10.1007/s12560-024-09614-2}
}
Kostenlos starten →