Clinical value of computed tomography in suspected prosthetic valve dysfunction
Netherlands Heart Journal · 2026-08 · 34 (7-8) · 265-273
DOI: 10.1007/s12471-026-02052-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Netherlands Heart Journal, online erschienen am 02.07.2026. Verfasst von Marco Voortman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Prosthetic valve dysfunction (PVD) is potentially life-threatening, yet often challenging to diagnose. We aimed to determine the negative and positive predictive value (NPV, PPV) of cardiac computed tomography (CT) in clinically suspected PVD.
Methods
Consecutive patients with prosthetic heart valves (PHVs), who underwent clinically indicated CT for suspected PVD between January 2017 and June 2024, were retrospectively assessed. CT scans with adequate image quality were evaluated and classified (abnormal: periprosthetic masses; structural valve deterioration (SVD); restricted leaflet motion). Valve-related adverse events and follow-up imaging were assessed to evaluate the diagnostic performance.
Results
Of all 64 patients (58.6 ± 16.9 years, 42.2% female), 68.8% had mechanical, 18.8% bioprosthetic, and 12.5% transcatheter PHV. CT findings were normal in 34 (53.1%) patients, with an NPV of 94% for ruling out device-related adverse events within a follow-up of 1 year. Among 30 (46.9%) patients with abnormal CT findings, a periprosthetic mass was identified in 21 (70%), including pannus ( n = 10), thrombus ( n = 6), vegetations ( n = 3). SVD was observed in 2 patients (6.7%). Among 23 patients with mechanical PHVs, 18 (78.3%) exhibited restricted leaflet motion. Surgical interventions confirmed CT abnormalities in 7/10 patients, yielding a 70% PPV.
Conclusion
This study is the first to demonstrate the high negative predictive value of CT for ruling out significant PVD-related complications, reinforcing its role as a reliable modality for ruling out major adverse events. While the PPV for identifying underlying PVD pathologies was moderate, CT effectively identified structural abnormalities that required intervention, supporting its clinical usefulness for comprehensive assessment of suspected PVD.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands.
- Department of Health Technology and Services Research, Faculty of Behavioral Management and Social Sciences, Technical Medical Center, University of Twente, Enschede, The Netherlands.
- Department of Radiology, Medisch Spectrum Twente, Enschede, The Netherlands.
- Department of Thoracic Surgery, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, The Netherlands.
- Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands. L.Wagenaar@mst.nl.
Zitieren
APA
Voortman, M., von Birgelen, C., Ties, D., Plonek, T., van Rosendael, A. R., Doggen, C. J. M., & Wagenaar, L. J. (2026). Clinical value of computed tomography in suspected prosthetic valve dysfunction. Netherlands Heart Journal, 34(7-8), 265-273. https://doi.org/10.1007/s12471-026-02052-8
Vancouver
Voortman M, von Birgelen C, Ties D, Plonek T, van Rosendael AR, Doggen CJM, et al. Clinical value of computed tomography in suspected prosthetic valve dysfunction. Netherlands Heart Journal. 2026;34(7-8):265-273. doi:10.1007/s12471-026-02052-8
BibTeX
@article{Voortman2026,
author = {Voortman, Marco and von Birgelen, Clemens and Ties, Daan and Plonek, Tomasz and van Rosendael, Alexander R and Doggen, Carine J M and Wagenaar, Lodewijk J},
title = {Clinical value of computed tomography in suspected prosthetic valve dysfunction},
journal = {Netherlands Heart Journal},
year = {2026},
volume = {34},
number = {7-8},
pages = {265--273},
doi = {10.1007/s12471-026-02052-8}
}
EUVIMED