Fachartikel in der Zeitschrift Exposure and Health, online erschienen am 04.08.2026. Verfasst von Iñaki Lacomba und 4 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Gefördert von: Conselleria de Sanitat Universal i Salut Pública, Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana, European Commission.
Abstract (Originalsprache)
All dioxins and dl-PCBs congeners were detected in the studied population. The median of the sum was 8.9 pg TEQ g^−1, whereas p95 reached 19.7 pg TEQ g^−1. Age emerged as the major predictor of dioxin concentrations. Even under the worst-case scenario (p95), no widespread health risks were identified. The persistence and accumulation of dioxins (PCDDs), furans (PCDFs) and dioxin-like polychlorinated biphenyl (dl-PCBs) continue to raise public health concerns. 480 serum samples from adults (18–65 years old) living in a Mediterranean Region of Spain were collected. All 29 congeners analysed were detected, with detection frequencies ranging from 3% (123789-HxCDF) to 100% (PCB-118, PCB-105, PCB-167, PCB-157, PCB-156, and PCB-189). Eight PCB congeners showed median concentrations exceeding 100 pg g^−1, with congener’s concentrations ranging from 0.13 pg g^−1 (PCB-81) to 15886.2 pg g^−1 (PCB-118). The congeners that contributed most, in terms of toxic equivalents (TEQ), were 12378-PCDD among PCDD/Fs and PCB-126 among dl-PCBs. The median total concentration of PCDD/Fs and dl-PCBs, expressed in TEQ, was 8.9 pg TEQ g^−1. In the worst-case scenario, expressed as percentile 95 (p95), obtained concentration was 19.7 pg TEQ g^−1. Overall, the total range of the sum oscillated from 2.8 pg TEQ g^−1 to 28.3 pg TEQ g^−1. As expected, a significant relationship was found between participants’ age and the overall score. Two main age groups were identified in the present study: 18–40 years and 41–65 years. Additionally, statistically significant effects were observed for smoking status, home location, gender, body mass index (BMI) and dietary consumption were revealed. A health risk assessment for PCDD, PCDF and dl-PCBs was carried out. Hazard index (HI) values for both the median and p95 were below the concerned level (HI < 1). However, 3% of the total analysed samples exhibited HI exceeding 1, suggesting potential risk in a small subset of the population. Graphical Abstract
Förderung
- Conselleria de Sanitat Universal i Salut Pública
- Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana
- European Commission
Zitieren
APA
Lacomba, I., López, A., Dualde, P., Pardo, O., & Coscollà, C. (2026). Concentrations, Exposure Predictors and Risk Assessment of Dioxins, Furans and Dioxin-Like PCBs in Spanish Serum Samples. Exposure and Health, 18(4). https://doi.org/10.1007/s12403-026-00797-6
Vancouver
Lacomba I, López A, Dualde P, Pardo O, Coscollà C. Concentrations, Exposure Predictors and Risk Assessment of Dioxins, Furans and Dioxin-Like PCBs in Spanish Serum Samples. Exposure and Health. 2026;18(4). doi:10.1007/s12403-026-00797-6
BibTeX
@article{Lacomba2026,
author = {Lacomba, Iñaki and López, Antonio and Dualde, Pablo and Pardo, Olga and Coscollà, Clara},
title = {Concentrations, Exposure Predictors and Risk Assessment of Dioxins, Furans and Dioxin-Like PCBs in Spanish Serum Samples},
journal = {Exposure and Health},
year = {2026},
volume = {18},
number = {4},
doi = {10.1007/s12403-026-00797-6}
}
EUVIMED