Validation of an AI-Powered Automated X-ray Bone Age Analyzer in Chinese Children and Adolescents: A Comparison with the Tanner–Whitehouse 3 Method
Advances in Therapy · 2024
DOI: 10.1007/s12325-024-02944-4 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Advances in Therapy, 2024. Verfasst von Yan Liang und 30 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Hauptthemen laut MEDLINE: Age Determination by Skeleton. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Key Research and Development Program of China.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
INTRODUCTION: Automated bone age assessment (BAA) is of growing interest because of its accuracy and time efficiency in daily practice. In this study, we validated the clinical applicability of a commercially available artificial intelligence (AI)-powered X-ray bone age analyzer equipped with a deep learning-based automated BAA system and compared its performance with that of the Tanner-Whitehouse 3 (TW-3) method. METHODS: Radiographs prospectively collected from 30 centers across various regions in China, including 900 Chinese children and adolescents, were assessed independently by six doctors (three experts and three residents) and an AI analyzer for TW3 radius, ulna, and short bones (RUS) and TW3 carpal bone age. The experts' mean estimates were accepted as the gold standard. The performance of the AI analyzer was compared with that of each resident. RESULTS: For the estimation of TW3-RUS, the AI analyzer had a mean absolute error (MAE) of 0.48 ± 0.42. The percentage of patients with an absolute error of < 1.0 years was 86.78%. The MAE was significantly lower than that of rater 1 (0.54 ± 0.49, P = 0.0068); however, it was not significant for rater 2 (0.48 ± 0.48) or rater 3 (0.49 ± 0.46). For TW3 carpal, the AI analyzer had an MAE of 0.48 ± 0.65. The percentage of patients with an absolute error of < 1.0 years was 88.78%. The MAE was significantly lower than that of rater 2 (0.58 ± 0.67, P = 0.0018) and numerically lower for rater 1 (0.54 ± 0.64) and rater 3 (0.50 ± 0.53). These results were consistent for the subgroups according to sex, and differences between the age groups were observed. CONCLUSION: In this comprehensive validation study conducted in China, an AI-powered X-ray bone age analyzer showed accuracies that matched or exceeded those of doctor raters. This method may improve the efficiency of clinical routines by reducing reading time without compromising accuracy. Assessing bone age, or how developed a child’s skeleton is, is important in medical care, but the standard method can be time-consuming. Using AI to automatically assess bone age from X-ray images may improve efficiency without reducing accuracy. In this study, we evaluated how well an AI-powered X-ray bone age analyzer performed compared to the established Tanner–Whitehouse 3 (TW-3) method. X-ray images from 900 Chinese children and adolescents were collected from 30 centers. Six doctors (three experts, three residents) and the AI system independently assessed the TW-3 radius, ulna, and short bones (RUS) and TW-3 carpal bone age. The experts’ assessments were considered the gold standard. The AI analyzer had an average error of 0.48 years for TW3-RUS bone age, with 87% of assessments within 1 year of the experts. For TW3 carpal bone age, the AI had an average error of 0.48 years, with 89% within 1 year. These results were similar to or better than those of the resident raters. These findings show the AI-powered analyzer can assess bone age as accurately as human raters. This technology may improve clinical efficiency by reducing the time required for bone age assessments without compromising accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatrics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
- Hubei Key Laboratory of Pediatric Genetic Metabolic and Endocrine Rare Diseases, Wuhan, 430030, China.
- Department of Endocrinology, Children's Hospital, Capital Institute of Pediatrics, Beijing, 100020, China.
- Department of Pediatrics, Tianjin Medical University General Hospital, Tianjin, 300052, China.
- Department of Pediatric Endocrine Genetics and Metabolism, Chengdu Women's and Children's Center Hospital, Chengdu, 610074, China.
- Department of Endocrinology, Shenzhen Children's Hospital, No. 7019 Yitian Road, Shenzhen, 518038, China.
ORCID-Profile: Xiaoping Luo
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Liang, Y., Chen, X., Zheng, R., Cheng, X., Su, Z., Wang, X., Du, H., Zhu, M., Li, G., Zhong, Y., Cheng, S., Yu, B., Yang, Y., Chen, R., Cui, L., Yao, H., Gu, Q., Gong, C., Jun, Z., …, & Luo, X. (2024). Validation of an AI-Powered Automated X-ray Bone Age Analyzer in Chinese Children and Adolescents: A Comparison with the Tanner–Whitehouse 3 Method. Advances in Therapy. https://doi.org/10.1007/s12325-024-02944-4
Vancouver
Liang Y, Chen X, Zheng R, Cheng X, Su Z, Wang X, et al. Validation of an AI-Powered Automated X-ray Bone Age Analyzer in Chinese Children and Adolescents: A Comparison with the Tanner–Whitehouse 3 Method. Advances in Therapy. 2024. doi:10.1007/s12325-024-02944-4
BibTeX
@article{Liang2024,
author = {Liang, Yan and Chen, Xiaobo and Zheng, Rongxiu and Cheng, Xinran and Su, Zhe and Wang, Xiumin and Du, Hongwei and Zhu, Min and Li, Guimei and Zhong, Yan and Cheng, Shengquan and Yu, Baosheng and Yang, Yu and Chen, Ruimin and Cui, Lanwei and Yao, Hui and Gu, Qiang and Gong, Chunxiu and Jun, Zhang and Huang, Xiaoyan and Liu, Deyun and Yan, Xueqin and Wei, Haiyan and Li, Yuwen and Zhang, Huifeng and Liu, Yanjie and Wang, Fengyun and Zhang, Gaixiu and Fan, Xin and Dai, Hongmei and Luo, Xiaoping},
title = {Validation of an AI-Powered Automated X-ray Bone Age Analyzer in Chinese Children and Adolescents: A Comparison with the Tanner–Whitehouse 3 Method},
journal = {Advances in Therapy},
year = {2024},
doi = {10.1007/s12325-024-02944-4}
}
EUVIMED