EUVIMEDEUVIMED entdecken
Vergleichsstudie

Clinical and biomechanical comparison of suture-external button versus interference screw associated with V–Y advancement or turndown flaps for flexor hallucis longus transfer in chronic Achilles tendon rupture

A R Vosoughi, A Akbarzadeh, S Brevis, A Kordi Yoosefinejad

MUSCULOSKELETAL SURGERY · 2024

DOI: 10.1007/s12306-024-00857-7 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift MUSCULOSKELETAL SURGERY, 2024. Verfasst von A R Vosoughi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedic & Rehabilitation Research Center, Shiraz University of Medical Sciences, Shiraz, Iran. Hauptthemen laut MEDLINE: Achilles Tendon, Tendon Transfer, Bone Screws, Suture Techniques. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Vice-Chancellor for Research, Shiraz University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Surgical treatment of chronic Achilles tendon rupture is a technically challenging procedure. We aimed to compare the clinical outcomes, range of motion, and strength of ankle plantar- and dorsiflexors between two techniques for fixation of flexor hallucis longus tendon to the calcaneus: interference screw and suture-external button. METHODS: Twenty-five patients participated in this retrospective comparative study. All patients underwent short harvest FHL tendon transfer for chronic AT rupture were asked for a follow-up visit, at least one year following surgery. The outcomes were evaluated by visual analog scale (VAS), AOFAS ankle-hindfoot score, and VISA-A questionnaire. Ankle ROM with possible restriction in addition to isokinetic strength of ankle plantar- and dorsiflexors was assessed. RESULTS: No statistically significant difference was observed between the groups for pain (P = 0.81), AOFAS ankle-hindfoot scale (P = 0.97), and VISA-A (P = 0.44). Notably, more decrease in ankle dorsiflexion was seen in interference screw group in comparison with suture-external button group (4.4 ± 6.6 vs. 9.5 ± 6.1 degrees, P = 0.06). The difference of active dorsiflexion between operated and non-operated side in interference screw group was statistically significant (P = 0.02). Biotenodesis screw imposed more limb asymmetry in comparison with suture-external button technique. CONCLUSIONS: Fixation of transcalcaneal FHL tendon transfer for chronic AT either by interference screw or suture-external button has encouraging postoperative clinical results. Although ROM of the ankle joint reduced in both techniques, interference screw may result in more reduction in dorsiflexion of the ankle.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Achilles TendonTendon TransferBone ScrewsSuture TechniquesSurgical FlapsTendon InjuriesHumansRetrospective StudiesMaleFemaleMiddle AgedRuptureAdultRange of Motion, ArticularChronic DiseaseTreatment OutcomeBiomechanical PhenomenaAged

Stichwörter der Autor:innen

Achilles tendonCalcaneusFlexor hallucis longusRepairRuptureTendon transfer

Autor:innen und Institutionen

  • Orthopedic & Rehabilitation Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Department of Orthopedic Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Orthopedic & Rehabilitation Research Center, Shiraz University of Medical Sciences, Shiraz, Iran. yoosefinejad@sums.ac.ir.
  • Physical Therapy Department, School of Rehabilitation Sciences, Shiraz University of Medical Sciences, Shiraz, Iran. yoosefinejad@sums.ac.ir.

Förderung

  • Vice-Chancellor for Research, Shiraz University of Medical Sciences

Zitieren

APA

Vosoughi, A. R., Akbarzadeh, A., Brevis, S., & Kordi Yoosefinejad, A. (2024). Clinical and biomechanical comparison of suture-external button versus interference screw associated with V–Y advancement or turndown flaps for flexor hallucis longus transfer in chronic Achilles tendon rupture. MUSCULOSKELETAL SURGERY. https://doi.org/10.1007/s12306-024-00857-7

Vancouver

Vosoughi AR, Akbarzadeh A, Brevis S, Kordi Yoosefinejad A. Clinical and biomechanical comparison of suture-external button versus interference screw associated with V–Y advancement or turndown flaps for flexor hallucis longus transfer in chronic Achilles tendon rupture. MUSCULOSKELETAL SURGERY. 2024. doi:10.1007/s12306-024-00857-7

BibTeX
@article{Vosoughi2024,
  author = {Vosoughi, A R and Akbarzadeh, A and Brevis, S and Kordi Yoosefinejad, A},
  title = {Clinical and biomechanical comparison of suture-external button versus interference screw associated with V–Y advancement or turndown flaps for flexor hallucis longus transfer in chronic Achilles tendon rupture},
  journal = {MUSCULOSKELETAL SURGERY},
  year = {2024},
  doi = {10.1007/s12306-024-00857-7}
}
Kostenlos starten →