Comparison of ultrasound visibility and retrieval success of two ultrasound-visible clips in targeted axillary dissection after neoadjuvant chemotherapy
Breast Cancer · 2026
DOI: 10.1007/s12282-026-01895-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Breast Cancer, 2026. Verfasst von Naomi Sakamoto und 2 weiteren Autor:innen. Beteiligte Einrichtung: Breast Center, Kameda Medical Center, 929 Higashi-cho, Kamogawa, Chiba, 296-0014, Japan. sakamoto.naomi@kameda.jp. Hauptthemen laut MEDLINE: Breast Neoplasms, Lymph Node Excision, Surgical Instruments. Die Arbeit nennt 33 Literaturangaben.
Themen: Onkologische Pflege
Abstract (Originalsprache)
Background
Targeted axillary dissection (TAD) is a less invasive alternative to axillary lymph node dissection (ALND) for patients with clinically node-positive breast cancer who convert to node-negative status after neoadjuvant chemotherapy (NAC). However, the effect of preoperative ultrasound visibility of different clip types on TAD outcomes remains unclear.
Methods
We conducted a single-center retrospective cohort study of patients with biopsy-proven axillary node-positive breast cancer who underwent NAC followed by TAD between August 2017 and December 2024. Two ultrasound-visible clips, the UltraCor™ Twirl™ (Twirl) and HydroMARK™, were evaluated. Outcomes included ultrasound visibility, clipped node retrieval success, localization techniques, and false-negative rate (FNR).
Results
Twenty-nine patients were included (Twirl, n = 15; HydroMARK, n = 14). Ultrasound visibility was higher with Twirl than with HydroMARK (86.7% versus 64.3%; p = 0.330). All Twirl cases underwent combined wire and dye-guided localization, whereas HydroMARK cases used multiple localization techniques. Retrieval success reached 100% with Twirl and 78.6% with HydroMARK ( p = 0.199). When clips were visible on ultrasound, retrieval rates were high for both clips at 100% for Twirl and 88.9% for HydroMARK ( p = 0.850). When clips were not clearly visible, Twirl maintained 100% retrieval compared with 60.0% for HydroMARK ( p = 0.895). Among patients who underwent scheduled ALND, the FNR of TAD was 0% (0/6).
Conclusions
Preoperative ultrasound visibility of the clip was associated with successful clip-based TAD. Twirl showed more consistent ultrasound visibility and retrieval success than HydroMARK, which suggests that Twirl may be a more reliable clip for routine clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Breast Center, Kameda Medical Center, 929 Higashi-cho, Kamogawa, Chiba, 296-0014, Japan. sakamoto.naomi@kameda.jp.
- Department of Clinical Epidemiology and Health Economics, School of Public Health, The University of Tokyo, Tokyo, Japan.
- Department of Clinical Research Support Office, Kameda Medical Center, Chiba, Japan.
- Breast Center, Kameda Medical Center, 929 Higashi-cho, Kamogawa, Chiba, 296-0014, Japan.
Zitieren
APA
Sakamoto, N., Matsui, H., & Fukuma, E. (2026). Comparison of ultrasound visibility and retrieval success of two ultrasound-visible clips in targeted axillary dissection after neoadjuvant chemotherapy. Breast Cancer. https://doi.org/10.1007/s12282-026-01895-8
Vancouver
Sakamoto N, Matsui H, Fukuma E. Comparison of ultrasound visibility and retrieval success of two ultrasound-visible clips in targeted axillary dissection after neoadjuvant chemotherapy. Breast Cancer. 2026. doi:10.1007/s12282-026-01895-8
BibTeX
@article{Sakamoto2026,
author = {Sakamoto, Naomi and Matsui, Hiroki and Fukuma, Eisuke},
title = {Comparison of ultrasound visibility and retrieval success of two ultrasound-visible clips in targeted axillary dissection after neoadjuvant chemotherapy},
journal = {Breast Cancer},
year = {2026},
doi = {10.1007/s12282-026-01895-8}
}
EUVIMED