Inter- and intra-observer variability of qualitative visual breast-composition assessment in mammography among Japanese physicians: a first multi-institutional observer performance study in Japan
Breast Cancer · 2024-07 · 31 (4) · 671-683
DOI: 10.1007/s12282-024-01580-8 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Breast Cancer, online erschienen am 15.04.2024. Verfasst von Yoichi Koyama und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Breast Surgical Oncology, Tokyo Medical University Hospital, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan. Hauptthemen laut MEDLINE: Observer Variation, Mammography, Breast Neoplasms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Visual assessment of mammographic breast composition remains the most common worldwide, although subjective variability limits its reproducibility. This study aimed to investigate the inter- and intra-observer variability in qualitative visual assessment of mammographic breast composition through a multi-institutional observer performance study for the first time in Japan. METHODS: This study enrolled 10 Japanese physicians from five different institutions. They used the new Japanese breast-composition classification system 4th edition to subjectively evaluate the breast composition in 200 pairs of right and left normal mediolateral oblique mammograms (number determined using precise sample size calculations) twice, with a 1-month interval (median patient age: 59 years [range 40-69 years]). The primary endpoint of this study was the inter-observer variability using kappa (κ) value. RESULTS: Inter-observer variability for the four and two classes of breast-composition assessment revealed moderate agreement (Fleiss' κ: first and second reading = 0.553 and 0.587, respectively) and substantial agreement (Fleiss' κ: first and second reading = 0.689 and 0.70, respectively). Intra-observer variability for the four and two classes of breast-composition assessment demonstrated substantial agreement (Cohen's κ, median = 0.758) and almost perfect agreement (Cohen's κ, median = 0.813). Assessments of consensus between the 10 physicians and the automated software Volpara® revealed slight agreement (Cohen's κ; first and second reading: 0.104 and 0.075, respectively). CONCLUSIONS: Qualitative visual assessment of mammographic breast composition using the new Japanese classification revealed excellent intra-observer reproducibility. However, persistent inter-observer variability, presenting a challenge in establishing it as the gold standard in Japan.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Breast Surgical Oncology, Tokyo Medical University Hospital, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
- Department of Breast Imaging and Breast Interventional Radiology, Shizuoka Cancer Center Hospital, 1007 Shimonagakubo, Suntogun Nagaizumicho, Shizuoka, 411-8777, Japan.
- Department of Health Data Science, Tokyo Medical University, 6-1-1 Shinjuku, Shinjuku-ku, Tokyo, 160-8402, Japan.
- Department of Radiology, St. Luke's International Hospital, 9-1 Akashi-cho, Chuo-ku, Tokyo, 104-8560, Japan.
- Department of Radiology, Breast and Imaging Center, St. Marianna University School of Medicine, 6-7-2 Mampukuji, Asao-Ward, Kawasaki, Kanagawa, 215-0004, Japan.
- Department of Surgery, Yokohama Sakae Kyosai Hospital, 132 Katsura-cho, Sakae-ku, Yokohama, Kanagawa, 247-8581, Japan.
Zitieren
APA
Koyama, Y., Nakashima, K., Orihara, S., Tsunoda, H., Kimura, F., Uenaka, N., Ban, K., Michishita, Y., Kanemaki, Y., Kurihara, A., Tawaraya, K., Taguri, M., Ishikawa, T., & Uematsu, T. (2024). Inter- and intra-observer variability of qualitative visual breast-composition assessment in mammography among Japanese physicians: a first multi-institutional observer performance study in Japan. Breast Cancer, 31(4), 671-683. https://doi.org/10.1007/s12282-024-01580-8
Vancouver
Koyama Y, Nakashima K, Orihara S, Tsunoda H, Kimura F, Uenaka N, et al. Inter- and intra-observer variability of qualitative visual breast-composition assessment in mammography among Japanese physicians: a first multi-institutional observer performance study in Japan. Breast Cancer. 2024;31(4):671-683. doi:10.1007/s12282-024-01580-8
BibTeX
@article{Koyama2024,
author = {Koyama, Yoichi and Nakashima, Kazuaki and Orihara, Shunichiro and Tsunoda, Hiroko and Kimura, Fuyo and Uenaka, Natsuki and Ban, Kanako and Michishita, Yukiko and Kanemaki, Yoshihide and Kurihara, Arisa and Tawaraya, Kanae and Taguri, Masataka and Ishikawa, Takashi and Uematsu, Takayoshi},
title = {Inter- and intra-observer variability of qualitative visual breast-composition assessment in mammography among Japanese physicians: a first multi-institutional observer performance study in Japan},
journal = {Breast Cancer},
year = {2024},
volume = {31},
number = {4},
pages = {671--683},
doi = {10.1007/s12282-024-01580-8}
}
EUVIMED