WGM microprobe device for high-sensitivity ultrasound detection and vibration spectrum measurement
Frontiers of Optoelectronics · 14.08.2025 · 18 (1)
DOI: 10.1007/s12200-025-00161-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers of Optoelectronics, online erschienen am 14.08.2025. Verfasst von Jialve Sun und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory for Advanced Optoelectronic Integrated Chips of Jiangsu Province, Peking University Yangtze Delta Institute of Optoelectronics, Nanton…. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Whispering-gallery-mode (WGM) microcavities have emerged as a promising alternative to traditional ultrasound probes, offering high sensitivity and wide bandwidth. In our research, we propose a novel silica WGM microprobe device, with impressive Q factors up to 10 7 . The side-coupled approach and special encapsulation design make the device compact, robust, and capable of utilizing in both gaseous and liquid environments. We have successfully conducted photoacoustic (PA) imaging on various samples using this device which demonstrates a high sensitivity of 5.4 mPa/√Hz and a broad bandwidth of 41 MHz at −6 dB for ultrasound. And it is capable of capturing the vibration spectrum of microparticles up to a few hundred megahertz. Our compact and lightweight device exhibits significant application potential in PA endoscopic detection, near-field ultrasound sensing and other aspects. Graphical Abstract
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory for Advanced Optoelectronic Integrated Chips of Jiangsu Province, Peking University Yangtze Delta Institute of Optoelectronics, Nantong, 226010, China. sunjl@ydioe.pku.edu.cn.
- Department of Electronic Engineering, Tsinghua University, Beijing, 100084, China. sunjl@ydioe.pku.edu.cn.
- Key Laboratory for Advanced Optoelectronic Integrated Chips of Jiangsu Province, Peking University Yangtze Delta Institute of Optoelectronics, Nantong, 226010, China.
- School of Physics, Peking University, Beijing, 100871, China.
- Key Laboratory for Advanced Optoelectronic Integrated Chips of Jiangsu Province, Peking University Yangtze Delta Institute of Optoelectronics, Nantong, 226010, China. fangxing.zhang@ydioe.pku.edu.cn.
Zitieren
APA
Sun, J., Huangfu, S., Chen, T., Cai, Z., Ruan, B., & Zhang, F. (2025). WGM microprobe device for high-sensitivity ultrasound detection and vibration spectrum measurement. Frontiers of Optoelectronics, 18(1). https://doi.org/10.1007/s12200-025-00161-7
Vancouver
Sun J, Huangfu S, Chen T, Cai Z, Ruan B, Zhang F. WGM microprobe device for high-sensitivity ultrasound detection and vibration spectrum measurement. Frontiers of Optoelectronics. 2025;18(1). doi:10.1007/s12200-025-00161-7
BibTeX
@article{Sun2025,
author = {Sun, Jialve and Huangfu, Shengnan and Chen, Tinglan and Cai, Zijing and Ruan, Bowen and Zhang, Fangxing},
title = {WGM microprobe device for high-sensitivity ultrasound detection and vibration spectrum measurement},
journal = {Frontiers of Optoelectronics},
year = {2025},
volume = {18},
number = {1},
doi = {10.1007/s12200-025-00161-7}
}
EUVIMED