EUVIMEDEUVIMED entdecken
Crossref

Monte Carlo-based three-dimensional dose evaluation for rotational cerebral angiography: peak dose to brain and skin and Dose–Volume Histogram (DVH) analysis of the brain

Hitoshi Miyazaki, Toshioh Fujibuchi, Donghee Han, Koji Oura, Hiroshi Hamasaki, Hideki Yoshikawa, Koichi Arimura, Toyoyuki Kato, Kousei Ishigami, Koji Yamashita

Radiological Physics and Technology · 11.11.2026

DOI: 10.1007/s12194-026-01167-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, online erschienen am 11.11.2026. Verfasst von Hitoshi Miyazaki und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1- 1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. miyazaki.…. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: Rotational cerebral angiography produces complex, nonuniform dose distributions; the mean brain dose may not sufficiently represent localized high-dose regions. This study aimed to visualize three-dimensional dose distributions in the brain and skin using PHITS, estimate peak brain dose (PBD) and peak skin dose (PSD), and evaluate the brain dose distribution using dose-volume histogram (DVH) analysis. MATERIALS AND METHODS: X-ray spectra for 3D digital subtraction angiography (3D-DSA, 70 kV) and cone-beam computed tomography (CBCT, 109 kV) were generated using SpekPy and implemented in PHITS. A rotational irradiation model covering approximately 200° was constructed using a multisource approach based on projection-dependent tube current-time product values. The model was validated using a PMMA phantom. Three-dimensional dose distributions were calculated using the adult male mesh-type reference computational phantom; PBD, PSD, and brain DVH indices were evaluated. RESULTS: Calculated doses agreed with measured values within 5.2%. Dose concentrations were mainly observed in the occipital region. The PBD and PSD were 25.1 and 44.1 mGy for 3D-DSA and 101.3 and 139.1 mGy for CBCT, respectively. The PBD was 3.3 times higher than the mean brain dose for 3D-DSA and 2.3 times higher for CBCT. DVH analysis showed that CBCT shifted the brain-dose distribution toward higher-dose regions, with D10% values of 14.9 and 70.0 mGy for 3D-DSA and CBCT, respectively. CONCLUSIONS: PHITS-based three-dimensional dose evaluation allowed localized high-dose regions in the brain and skin to be visualized and quantified. DVH analysis complemented the peak dose assessment by providing volumetric information on the brain-dose distribution.

Schlagwörter

Stichwörter der Autor:innen

Dose–volume histogramMonte Carlo simulationPHITSPeak brain dosePeak skin doseRotational cerebral angiography

Autor:innen und Institutionen

  • Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1- 1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. miyazaki.hitoshi.036@m.kyushu-u.ac.jp.
  • Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. miyazaki.hitoshi.036@m.kyushu-u.ac.jp.
  • Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812- 8582, Japan.
  • Department of Radiological Science, Kangwon National University, Samcheok, 25949, Republic of Korea.
  • Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1- 1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.

Zitieren

APA

Miyazaki, H., Fujibuchi, T., Han, D., Oura, K., Hamasaki, H., Yoshikawa, H., Arimura, K., Kato, T., Ishigami, K., & Yamashita, K. (2026). Monte Carlo-based three-dimensional dose evaluation for rotational cerebral angiography: peak dose to brain and skin and Dose–Volume Histogram (DVH) analysis of the brain. Radiological Physics and Technology. https://doi.org/10.1007/s12194-026-01167-2

Vancouver

Miyazaki H, Fujibuchi T, Han D, Oura K, Hamasaki H, Yoshikawa H, et al. Monte Carlo-based three-dimensional dose evaluation for rotational cerebral angiography: peak dose to brain and skin and Dose–Volume Histogram (DVH) analysis of the brain. Radiological Physics and Technology. 2026. doi:10.1007/s12194-026-01167-2

BibTeX
@article{Miyazaki2026,
  author = {Miyazaki, Hitoshi and Fujibuchi, Toshioh and Han, Donghee and Oura, Koji and Hamasaki, Hiroshi and Yoshikawa, Hideki and Arimura, Koichi and Kato, Toyoyuki and Ishigami, Kousei and Yamashita, Koji},
  title = {Monte Carlo-based three-dimensional dose evaluation for rotational cerebral angiography: peak dose to brain and skin and Dose–Volume Histogram (DVH) analysis of the brain},
  journal = {Radiological Physics and Technology},
  year = {2026},
  doi = {10.1007/s12194-026-01167-2}
}
Kostenlos starten →