Fachartikel in der Zeitschrift Radiological Physics and Technology, online erschienen am 28.10.2026. Verfasst von Katsunori Yamashita und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hamamatsu University Hospital, Hamamatsu, Shizuoka, Japan. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Echocardiographers (ECs) often stand close to the patient during structural heart interventions (SHIs) and may receive higher occupational radiation exposure than interventional cardiologists (ICs). Previous studies have relied on cumulative dose measurements, leaving the per-event determinants of occupational radiation dose poorly characterized. We quantified the per-event personal dose equivalent rate at a 10-mm depth [ H _p(10)] for ECs and ICs during SHIs and identified its determinants. We prospectively analyzed 37 SHI cases (20 mitral transcatheter edge-to-edge repair procedures and 17 left atrial appendage occlusion procedures) at a single center between March 2024 and March 2025. The EC and IC each wore two semiconductor dosimeters (on the front and side of the neck) sampling at 1 Hz, and the higher reading was used for analysis. Per-event H _p(10) rates were calculated by integrating dosimetry data, radiation dose structured report information, and video-based shielding labels. A prespecified linear mixed-effects model with a case-level random intercept assessed X-ray output, beam geometry, operator shielding, and C-arm angulation as candidate determinants for each operator. Among 3,222 exposure events, the EC-to-IC ratio of the H _p(10) rate was 2.3 during fluoroscopy and 3.8 during cine acquisition (both p < 0.001). In the multivariable model, log_10( K _a,r rate), protocol, C-arm angle, source-to-detector distance, field of view, and operator shielding were independent predictors of the H _p(10) rate for both operators. The EC experienced substantially higher per-event H _p(10) rates than the IC, particularly during cine acquisition. Operator-specific shielding strategies and per-event optimization of X-ray output are warranted.

Schlagwörter

Stichwörter der Autor:innen

EchocardiographyLinear mixed-effects modelOccupational radiation exposurePersonal dose equivalentRadiation protectionStructural heart intervention

Autor:innen und Institutionen

  • Department of Radiology, Hamamatsu University Hospital, Hamamatsu, Shizuoka, Japan.
  • Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan.
  • Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan. k.matsubara@st…

Zitieren

APA

Yamashita, K., & Matsubara, K. (2026). Quantifying per-event dose-equivalent rates of echocardiographers and interventional cardiologists during structural heart interventions. Radiological Physics and Technology. https://doi.org/10.1007/s12194-026-01161-8

Vancouver

Yamashita K, Matsubara K. Quantifying per-event dose-equivalent rates of echocardiographers and interventional cardiologists during structural heart interventions. Radiological Physics and Technology. 2026. doi:10.1007/s12194-026-01161-8

BibTeX
@article{Yamashita2026,
  author = {Yamashita, Katsunori and Matsubara, Kosuke},
  title = {Quantifying per-event dose-equivalent rates of echocardiographers and interventional cardiologists during structural heart interventions},
  journal = {Radiological Physics and Technology},
  year = {2026},
  doi = {10.1007/s12194-026-01161-8}
}
Kostenlos starten →