Impact of added filtration and field size on operator eye lens exposure in over-table fluoroscopy: a Monte Carlo simulation study

Takayuki Tamura, Kaito Hoashi, Yoshifumi Masumoto, Shingo Hamaoka

Radiological Physics and Technology · 2026-06 · 19 (2) · 885-890

DOI: 10.1007/s12194-026-01062-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, online erschienen am 02.05.2026. Verfasst von Takayuki Tamura und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Radiology, Faculty of Health Sciences, Hiroshima International University, Higashi-Hiroshima, 739-2695, Japan. t-tamura@hiroko…. Hauptthemen laut MEDLINE: Monte Carlo Method, Lens, Crystalline, Filtration, Occupational Exposure. Die Arbeit nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study characterized operator eye lens exposure in over-table fluoroscopy using Monte Carlo simulation, focusing on beam quality and geometry under simulated conditions. Absorbed doses were calculated using voxel phantoms across tube voltages (75–95 kV), filtrations (Al 2.5–4.5 mm, Cu 0.0–0.5 mm), and field sizes (10–30 cm). Grid correction was applied to normalize results to detector entrance dose. Beam hardening via increased filtration significantly reduced lens doses, although the rate of dose reduction gradually diminished as Cu thickness increased. Field size reduction was the most effective strategy; a 10 cm field reduced the dose by 40–50% compared to a 30 cm field. When using Patient Entrance Reference Point (PERP) values to estimate operator lens exposure, beam quality must be considered, as the same PERP value can yield substantially different operator doses depending on filtration. Field size restriction remains the most effective measure for dose reduction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodLens, CrystallineFiltrationOccupational ExposureFluoroscopyRadiation DosageHumansPhantoms, Imaging

Stichwörter der Autor:innen

Eye lens doseMonte Carlo simulationOver-table fluoroscopyRadiation protection

Autor:innen und Institutionen

  • Department of Clinical Radiology, Faculty of Health Sciences, Hiroshima International University, Higashi-Hiroshima, 739-2695, Japan. t-tamura@hirokoku-u.ac.jp.
  • Section of Diagnostic Imaging, Department of Clinical Support, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan.

Zitieren

APA

Tamura, T., Hoashi, K., Masumoto, Y., & Hamaoka, S. (2026). Impact of added filtration and field size on operator eye lens exposure in over-table fluoroscopy: a Monte Carlo simulation study. Radiological Physics and Technology, 19(2), 885-890. https://doi.org/10.1007/s12194-026-01062-w

Vancouver

Tamura T, Hoashi K, Masumoto Y, Hamaoka S. Impact of added filtration and field size on operator eye lens exposure in over-table fluoroscopy: a Monte Carlo simulation study. Radiological Physics and Technology. 2026;19(2):885-890. doi:10.1007/s12194-026-01062-w

BibTeX
@article{Tamura2026,
  author = {Tamura, Takayuki and Hoashi, Kaito and Masumoto, Yoshifumi and Hamaoka, Shingo},
  title = {Impact of added filtration and field size on operator eye lens exposure in over-table fluoroscopy: a Monte Carlo simulation study},
  journal = {Radiological Physics and Technology},
  year = {2026},
  volume = {19},
  number = {2},
  pages = {885--890},
  doi = {10.1007/s12194-026-01062-w}
}
Kostenlos starten →